Literature DB >> 17081867

Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography.

Maolong Tang1, Yan Li, Mariana Avila, David Huang.   

Abstract

PURPOSE: To measure total corneal power using optical coherence tomography (OCT).
SETTING: Refractive surgery practices at 2 academic eye centers in Cleveland, Ohio, and Los Angeles, California, USA.
METHODS: Thirty-two eyes of 17 patients having myopic laser in situ keratomileusis (LASIK) were enrolled in a prospective observational study. Manifest refraction, OCT, and Placido ring corneal topography with the Atlas 995 (Carl Zeiss Meditec, Inc.) were performed preoperatively and 3 months after laser in situ keratomileusis (LASIK). A high-speed (2000 axial scans/second) corneal and anterior segment OCT prototype was used. The total corneal power was calculated by summation of the anterior and posterior surface powers, and the value was compared with that determined by simulated keratometry. Two methods of measuring total corneal power were tested: the direct method, which used OCT to measure both corneal surfaces directly, and the hybrid method, which combined OCT with anterior corneal topography.
RESULTS: The repeatability (pooled standard deviation) of measuring total corneal power using the hybrid method was 3 times better than that using the direct method. It was 0.23 diopter (D) before LASIK and 0.26 D after LASIK. Preoperative total power was 1.13 D (2.6%) lower than the simulated keratometry. Compared to the LASIK-induced change in spherical equivalent refraction, the change in total corneal power was equivalent, while the change in simulated keratometry power was significantly smaller (-18.8%) (P<.001).
CONCLUSIONS: Keratometry using the traditional index of 1.3375 overestimated the total power in preoperative corneas and underestimated LASIK-induced refractive change. Measuring both corneal surfaces using a combination of OCT and Placido ring topography provided a better measure of total corneal power that closely tracked the refractive change in post-LASIK eyes.

Entities:  

Mesh:

Year:  2006        PMID: 17081867      PMCID: PMC1808223          DOI: 10.1016/j.jcrs.2006.04.046

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  23 in total

1.  Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis.

Authors:  S Srivannaboon; D Z Reinstein; H F Sutton; S P Holland
Journal:  J Cataract Refract Surg       Date:  1999-12       Impact factor: 3.351

2.  Refractive error in cataract surgery after previous refractive surgery.

Authors:  H Gimbel; R Sun; G B Kaye
Journal:  J Cataract Refract Surg       Date:  2000-01       Impact factor: 3.351

3.  Intraocular lens power calculations using corneal topography after photorefractive keratectomy.

Authors:  J G Ladas; B S Boxer Wachler; J D Hunkeler; D S Durrie
Journal:  Am J Ophthalmol       Date:  2001-08       Impact factor: 5.258

4.  Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy.

Authors:  H V Gimbel; R Sun; M T Furlong; J A van Westenbrugge; J Kassab
Journal:  J Cataract Refract Surg       Date:  2000-08       Impact factor: 3.351

5.  A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis.

Authors:  Sergio Sónego-Krone; Gerson López-Moreno; Oscar V Beaujon-Balbi; Carlos G Arce; Paulo Schor; Mauro Campos
Journal:  Arch Ophthalmol       Date:  2004-02

6.  Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation.

Authors:  M Leyland
Journal:  Eye (Lond)       Date:  2004-04       Impact factor: 3.775

7.  Anterior chamber width measurement by high-speed optical coherence tomography.

Authors:  Jason A Goldsmith; Yan Li; Maria Regina Chalita; Volker Westphal; Chetan A Patil; Andrew M Rollins; Joseph A Izatt; David Huang
Journal:  Ophthalmology       Date:  2005-02       Impact factor: 12.079

8.  115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser.

Authors:  W Y Oh; S H Yun; G J Tearney; B E Bouma
Journal:  Opt Lett       Date:  2005-12-01       Impact factor: 3.776

9.  Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography.

Authors:  J S Schuman; M R Hee; C A Puliafito; C Wong; T Pedut-Kloizman; C P Lin; E Hertzmark; J A Izatt; E A Swanson; J G Fujimoto
Journal:  Arch Ophthalmol       Date:  1995-05

10.  Intraocular lens power calculation following LASIK: determination of the new effective index of refraction.

Authors:  Elias F Jarade; Françoise C Abi Nader; Khalid F Tabbara
Journal:  J Refract Surg       Date:  2006 Jan-Feb       Impact factor: 3.573

View more
  26 in total

1.  High-speed optical coherence tomography for management after laser in situ keratomileusis.

Authors:  Mariana Avila; Yan Li; Jonathan C Song; David Huang
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

2.  [Measurement of the central corneal power after myopic LASIK].

Authors:  C-A Lackerbauer; L Hartmann; S Fröhlich; M Schaumberger; A Kollias
Journal:  Ophthalmologe       Date:  2008-01       Impact factor: 1.059

3.  Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  Saudi J Ophthalmol       Date:  2012-01

Review 4.  Optical coherence tomography: history, current status, and laboratory work.

Authors:  Michelle L Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Larry Kagemann; Juan Xu; Lindsey S Folio; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-14       Impact factor: 4.799

5.  An intraocular lens power calculation formula based on optical coherence tomography: a pilot study.

Authors:  Maolong Tang; Yan Li; David Huang
Journal:  J Refract Surg       Date:  2010-06-17       Impact factor: 3.573

6.  Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2012-04       Impact factor: 3.351

7.  Corneal power measurement with Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Alex Chen; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2010-12       Impact factor: 3.351

8.  Optical coherence tomography accurately measures corneal power change from laser refractive surgery.

Authors:  Ryan P McNabb; Sina Farsiu; Sandra S Stinnett; Joseph A Izatt; Anthony N Kuo
Journal:  Ophthalmology       Date:  2014-12-06       Impact factor: 12.079

9.  Quantitative single and multi-surface clinical corneal topography utilizing optical coherence tomography.

Authors:  Ryan P McNabb; Anthony N Kuo; Joseph A Izatt
Journal:  Opt Lett       Date:  2013-04-15       Impact factor: 3.776

10.  Keratoconus diagnosis with optical coherence tomography pachymetry mapping.

Authors:  Yan Li; David M Meisler; Maolong Tang; Ake T H Lu; Vishakha Thakrar; Bibiana J Reiser; David Huang
Journal:  Ophthalmology       Date:  2008-11-05       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.