Literature DB >> 10609202

Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis.

S Srivannaboon1, D Z Reinstein, H F Sutton, S P Holland.   

Abstract

PURPOSE: To determine whether the refractive change obtained using the Orbscan-derived total optical power (TOP) map is in concordance with the manifest refractive change produced by laser in situ keratomileusis (LASIK).
SETTING: LASIK Vision Canada, Vancouver, BC, Canada (an ambulatory surgical center for refractive surgery).
METHODS: Twenty eyes of 10 consecutive bilateral LASIK patients were included in the study. Orbscan topographical analysis and manifest refraction were performed preoperatively and at least 1 month postoperatively. The change in manifest refraction (corrected to the corneal plane) before and after LASIK was correlated with the corneal power change averaged within the 2.0, 3.0, 4.0, and 5.0 mm diameter zones of TOP and axial power maps.
RESULTS: The central 4.0 mm zone TOP map gave the best correlation between manifest refractive change and Orbscan-measured corneal power change (r2 = 0.835, P < .004). The correlation was higher with TOP maps than with anterior axial power maps.
CONCLUSION: The corneal power change measured by the Orbscan TOP maps correlated highly with the changes in manifest refraction after LASIK.

Entities:  

Mesh:

Year:  1999        PMID: 10609202     DOI: 10.1016/s0886-3350(99)00286-2

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography.

Authors:  Maolong Tang; Yan Li; Mariana Avila; David Huang
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

2.  [Measurement of the central corneal power after myopic LASIK].

Authors:  C-A Lackerbauer; L Hartmann; S Fröhlich; M Schaumberger; A Kollias
Journal:  Ophthalmologe       Date:  2008-01       Impact factor: 1.059

3.  Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  Saudi J Ophthalmol       Date:  2012-01

4.  An intraocular lens power calculation formula based on optical coherence tomography: a pilot study.

Authors:  Maolong Tang; Yan Li; David Huang
Journal:  J Refract Surg       Date:  2010-06-17       Impact factor: 3.573

5.  Intraocular lens power calculation after previous myopic laser vision correction based on corneal power measured by Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2012-04       Impact factor: 3.351

6.  Corneal power measurement with Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Alex Chen; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2010-12       Impact factor: 3.351

7.  Day to Day Clinically Relevant Corneal Elevation, Thickness, and Curvature Parameters Using the Orbscan II Scanning Slit Topographer and the Pentacam Scheimpflug Imaging Device.

Authors:  Hassan Hashemi; Shiva Mehravaran
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

8.  Optical System Design for Noncontact, Normal Incidence, THz Imaging of in vivo Human Cornea.

Authors:  Shijun Sung; Shahab Dabironezare; Nuria Llombart; Skyler Selvin; Neha Bajwa; Somporn Chantra; Bryan Nowroozi; James Garritano; Jacob Goell; Alex Li; Sophie X Deng; Elliott Brown; Warren S Grundfest; Zachary D Taylor
Journal:  IEEE Trans Terahertz Sci Technol       Date:  2017-11-22       Impact factor: 3.274

9.  Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis).

Authors:  David Huang; Maolong Tang; Li Wang; Xinbo Zhang; Rebecca L Armour; Devin M Gattey; Lorinna H Lombardi; Douglas D Koch
Journal:  Trans Am Ophthalmol Soc       Date:  2013-09

10.  Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.

Authors:  Kaevalin Lekhanont; Manachai Nonpassopon; Khemruetai Wannarosapark; Varintorn Chuckpaiwong
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.