Literature DB >> 11008040

Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy.

H V Gimbel1, R Sun, M T Furlong, J A van Westenbrugge, J Kassab.   

Abstract

PURPOSE: To investigate the accuracy and predictability of intraocular lens (IOL) power calculation in postoperative photorefractive keratectomy (PRK) eyes.
SETTING: Gimbel Eye Centre, Calgary, Alberta, Canada.
METHODS: The results in 5 cataract surgery eyes that had had PRK were analyzed retrospectively. Target refractions based on actual and refraction-derived keratometric values were compared with postoperative achieved refractions. The target refractions calculated using 5 IOL formulas and 2 A-constants were also compared with the achieved refractions.
RESULTS: In postoperative PRK eyes, the power calculation was more accurate and predictable when the smaller of either the actual or refraction-derived keratometric value was used to calculate the IOL power. The difference between target and achieved refractions appeared smaller when the Binkhorst formula was used. No significant hyperopic shift was observed after cataract surgery.
CONCLUSION: The smaller of the actual or the refraction-derived keratometric value is recommended for calculating IOL power in post-PRK eyes.

Entities:  

Mesh:

Year:  2000        PMID: 11008040     DOI: 10.1016/s0886-3350(00)00480-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Light-adjustable lens: development of in vitro nomograms.

Authors:  Daniel M Schwartz; Christian A Sandstedt; Shiao H Chang; Julie A Kornfield; Robert H Grubbs
Journal:  Trans Am Ophthalmol Soc       Date:  2004

2.  Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography.

Authors:  Maolong Tang; Yan Li; Mariana Avila; David Huang
Journal:  J Cataract Refract Surg       Date:  2006-11       Impact factor: 3.351

3.  Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes.

Authors:  Wei Zhu; Feng-Ju Zhang; Yu Li; Yan-Zheng Song
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

4.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

5.  Intraocular lens power calculation after corneal refractive surgery.

Authors:  Vahid Feiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

6.  The comparison of central and mean true-net power (Pentacam) in calculating IOL-power after refractive surgery.

Authors:  Jeong-Ho Yi; Joo Youn Shin; Byoung Jin Ha; Sang Woo Kim; Beom Jin Cho; Eung Kweon Kim; Tae-im Kim
Journal:  Korean J Ophthalmol       Date:  2009-03-09

7.  Development of a New Method for Calculating Intraocular Lens Power after Myopic Laser In Situ Keratomileusis by Combining the Anterior-Posterior Ratio of the Corneal Radius of the Curvature with the Double-K Method.

Authors:  Yoshihiko Iida; Kimiya Shimizu; Nobuyuki Shoji
Journal:  J Clin Med       Date:  2022-01-20       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.