Literature DB >> 17036300

Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

Elliot R McVeigh1, Michael A Guttman, Robert J Lederman, Ming Li, Ozgur Kocaturk, Timothy Hunt, Shawn Kozlov, Keith A Horvath.   

Abstract

Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct apical access in eight porcine hearts. A clinical stentless bioprosthetic valve affixed to a platinum stent was compressed onto a balloon-tipped catheter. This was fed through a 15-18-mm delivery port inserted into the left ventricular (LV) apex via a minimally invasive subxyphoid incision. Using interactive real-time MRI, the surgeon implanted the prosthetic valve in the correct location at the aortic annulus within 90 s. In four of the animals immediately after implantation, ventricular function, blood flow through the valve, and myocardial perfusion were evaluated with MRI. MRI-guided beating-heart surgery may provide patients with a less morbid and more durable solution to structural heart disease. Published 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 17036300      PMCID: PMC1963465          DOI: 10.1002/mrm.21044

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Cardiac valve operations using a partial sternotomy (lower half) technique.

Authors:  D B Doty; J H Flores; J R Doty
Journal:  J Card Surg       Date:  2000 Jan-Feb       Impact factor: 1.620

2.  Catheter-based endomyocardial injection with real-time magnetic resonance imaging.

Authors:  Robert J Lederman; Michael A Guttman; Dana C Peters; Richard B Thompson; Jonathan M Sorger; Alexander J Dick; Venkatesh K Raman; Elliot R McVeigh
Journal:  Circulation       Date:  2002-03-19       Impact factor: 29.690

3.  Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.

Authors:  Michael A Guttman; Peter Kellman; Alexander J Dick; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

Review 4.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

Review 5.  Interventional and intraoperative MRI at low field scanner--a review.

Authors:  Roberto T Blanco; Risto Ojala; Juho Kariniemi; Jukka Perälä; Jaakko Niinimäki; Osmo Tervonen
Journal:  Eur J Radiol       Date:  2005-11       Impact factor: 3.528

6.  Steps toward the percutaneous replacement of atrioventricular valves an experimental study.

Authors:  Younes Boudjemline; Gabriella Agnoletti; Damien Bonnet; Luc Behr; Nicolas Borenstein; Daniel Sidi; Philipp Bonhoeffer
Journal:  J Am Coll Cardiol       Date:  2005-07-19       Impact factor: 24.094

7.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

Authors:  Venkatesh K Raman; Parag V Karmarkar; Michael A Guttman; Alexander J Dick; Dana C Peters; Cengizhan Ozturk; Breno S S Pessanha; Richard B Thompson; Amish N Raval; Ranil DeSilva; Ronnier J Aviles; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  J Am Coll Cardiol       Date:  2005-06-21       Impact factor: 24.094

8.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

9.  Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in Swine.

Authors:  Alexander J Dick; Michael A Guttman; Venkatesh K Raman; Dana C Peters; Breno S S Pessanha; Jonathan M Hill; Scott Smith; Greig Scott; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2003-12-01       Impact factor: 29.690

10.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience.

Authors:  Alain Cribier; Helene Eltchaninoff; Christophe Tron; Fabrice Bauer; Carla Agatiello; Deborah Nercolini; Sydney Tapiero; Pierre-Yves Litzler; Jean-Paul Bessou; Vasilis Babaliaros
Journal:  J Am Coll Cardiol       Date:  2006-02-09       Impact factor: 24.094

View more
  29 in total

Review 1.  Multimodality cardiovascular molecular imaging technology.

Authors:  Matthew O'Donnell; Elliot R McVeigh; H William Strauss; Atsushi Tanaka; Brett E Bouma; Guillermo J Tearney; Michael A Guttman; Ernest V Garcia
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  Transapical aortic valve replacement under real-time magnetic resonance imaging guidance: experimental results with balloon-expandable and self-expanding stents.

Authors:  Keith A Horvath; Dumitru Mazilu; Ozgur Kocaturk; Ming Li
Journal:  Eur J Cardiothorac Surg       Date:  2010-10-22       Impact factor: 4.191

3.  Closed-bore XMR (CBXMR) systems for aortic valve replacement: x-ray tube imaging performance.

Authors:  John A Bracken; Philip Komljenovic; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

4.  Self-Expanding Stent and Delivery System for Aortic Valve Replacement.

Authors:  Dumitru Mazilu; Ming Li; Ozgur Kocaturk; Keith A Horvath
Journal:  J Med Device       Date:  2012-11-01       Impact factor: 0.582

5.  Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy.

Authors:  Cristian A Linte; John Moore; Chris Wedlake; Daniel Bainbridge; Gérard M Guiraudon; Douglas L Jones; Terry M Peters
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-11-15       Impact factor: 2.924

6.  Closed bore XMR (CBXMR) systems for aortic valve replacement: investigation of rotating-anode x-ray tube heat loadability.

Authors:  John A Bracken; Prasheel V Lillaney; Rebecca Fahrig; J A Rowlands
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

Review 7.  Real-time magnetic resonance imaging guidance for cardiovascular procedures.

Authors:  Keith A Horvath; Ming Li; Dumitru Mazilu; Michael A Guttman; Elliot R McVeigh
Journal:  Semin Thorac Cardiovasc Surg       Date:  2007

8.  Comparison of three artificial models of the magnetohydrodynamic effect on the electrocardiogram.

Authors:  Julien Oster; Raul Llinares; Stephen Payne; Zion Tsz Ho Tse; Ehud Jeruham Schmidt; Gari D Clifford
Journal:  Comput Methods Biomech Biomed Engin       Date:  2014-04-24       Impact factor: 1.763

Review 9.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

10.  Midterm results of transapical aortic valve replacement via real-time magnetic resonance imaging guidance.

Authors:  Keith A Horvath; Dumitru Mazilu; Michael Guttman; Arthur Zetts; Timothy Hunt; Ming Li
Journal:  J Thorac Cardiovasc Surg       Date:  2009-12-06       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.