Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Christina E Saikus1, Robert J Lederman.   

Abstract

Cardiovascular magnetic resonance (CMR) combines excellent soft-tissue contrast, multiplanar views, and dynamic imaging of cardiac function without ionizing radiation exposure. Interventional cardiovascular magnetic resonance (iCMR) leverages these features to enhance conventional interventional procedures or to enable novel ones. Although still awaiting clinical deployment, this young field has tremendous potential. We survey promising clinical applications for iCMR. Next, we discuss the technologies that allow CMR-guided interventions and, finally, what still needs to be done to bring them to the clinic.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19909937      PMCID: PMC2843404          DOI: 10.1016/j.jcmg.2009.09.002

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  89 in total

1.  Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time.

Authors:  Timm Dickfeld; Hugh Calkins; Muz Zviman; Ritsushi Kato; Glenn Meininger; Lars Lickfett; Ron Berger; Henry Halperin; Stephen B Solomon
Journal:  Circulation       Date:  2003-10-20       Impact factor: 29.690

2.  Image-based tracking of optically detunable parallel resonant circuits.

Authors:  Holger Eggers; Steffen Weiss; Peter Boernert; Peter Boesiger
Journal:  Magn Reson Med       Date:  2003-06       Impact factor: 4.668

Review 3.  Interventional robotic systems: applications and technology state-of-the-art.

Authors:  Kevin Cleary; Andreas Melzer; Vance Watson; Gernot Kronreif; Dan Stoianovici
Journal:  Minim Invasive Ther Allied Technol       Date:  2006       Impact factor: 2.442

4.  Flexible real-time magnetic resonance imaging framework.

Authors:  Juan M Santos; Graham A Wright; John M Pauly
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

5.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

Review 6.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

Review 7.  MRI-guided interventions of the musculoskeletal system.

Authors:  Kevin A Smith; John A Carrino; John Carrino
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

8.  Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery.

Authors:  V M Tronnier; C R Wirtz; M Knauth; G Lenz; O Pastyr; M M Bonsanto; F K Albert; R Kuth; A Staubert; W Schlegel; K Sartor; S Kunze
Journal:  Neurosurgery       Date:  1997-05       Impact factor: 4.654

9.  Electroanatomic mapping of the left ventricle in a porcine model of chronic myocardial infarction with magnetic resonance-based catheter tracking.

Authors:  Srinivas R Dukkipati; Richard Mallozzi; Ehud J Schmidt; Godtfred Holmvang; Andre d'Avila; Renee Guhde; Robert D Darrow; Glenn Slavin; Maggie Fung; Zachary Malchano; Greg Kampa; Jeremy D Dando; Christina McPherson; Thomas K Foo; Jeremy N Ruskin; Charles L Dumoulin; Vivek Y Reddy
Journal:  Circulation       Date:  2008-08-04       Impact factor: 29.690

10.  Active two-channel 0.035'' guidewire for interventional cardiovascular MRI.

Authors:  Ozgur Kocaturk; Ann H Kim; Christina E Saikus; Michael A Guttman; Anthony Z Faranesh; Cengizhan Ozturk; Robert J Lederman
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

View more
  26 in total

1.  MRI-guided vascular access with an active visualization needle.

Authors:  Christina E Saikus; Kanishka Ratnayaka; Israel M Barbash; Jessica H Colyer; Ozgur Kocaturk; Anthony Z Faranesh; Robert J Lederman
Journal:  J Magn Reson Imaging       Date:  2011-11       Impact factor: 4.813

2.  Catheter tip tracking for MR-guided interventions using discrete Kalman filter and mean shift localization.

Authors:  Abubakr Eldirdiri; Frédéric Courivaud; Rafael Palomar; Per Kristian Hol; Ole Jakob Elle
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-08-23       Impact factor: 2.924

3.  Comparison of three artificial models of the magnetohydrodynamic effect on the electrocardiogram.

Authors:  Julien Oster; Raul Llinares; Stephen Payne; Zion Tsz Ho Tse; Ehud Jeruham Schmidt; Gari D Clifford
Journal:  Comput Methods Biomech Biomed Engin       Date:  2014-04-24       Impact factor: 1.763

4.  A Platform Integrating Acquisition, Reconstruction, Visualization, and Manipulator Control Modules for MRI-Guided Interventions.

Authors:  Jose D Velazco Garcia; Nikhil V Navkar; Dawei Gui; Cristina M Morales; Eftychios G Christoforou; Alpay Ozcan; Julien Abinahed; Abdulla Al-Ansari; Andrew Webb; Ioannis Seimenis; Nikolaos V Tsekos
Journal:  J Digit Imaging       Date:  2019-06       Impact factor: 4.056

Review 5.  A new look at the heart-novel imaging techniques.

Authors:  C M Johnston; A J Krafft; M F Russe; E A Rog-Zielinska
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-12-14

6.  Active delivery cable tuned to device deployment state: enhanced visibility of nitinol occluders during preclinical interventional MRI.

Authors:  Jamie A Bell; Christina E Saikus; Kanishka Ratnayaka; Israel M Barbash; Anthony Z Faranesh; Dominique N Franson; Merdim Sonmez; Michael C Slack; Robert J Lederman; Ozgur Kocaturk
Journal:  J Magn Reson Imaging       Date:  2012-06-15       Impact factor: 4.813

Review 7.  Real-time MRI guidance of cardiac interventions.

Authors:  Adrienne E Campbell-Washburn; Mohammad A Tavallaei; Mihaela Pop; Elena K Grant; Henry Chubb; Kawal Rhode; Graham A Wright
Journal:  J Magn Reson Imaging       Date:  2017-05-11       Impact factor: 4.813

8.  A deflectable guiding catheter for real-time MRI-guided interventions.

Authors:  Jamie A Bell; Christina E Saikus; Kanishka Ratnayaka; Vincent Wu; Merdim Sonmez; Anthony Z Faranesh; Jessica H Colyer; Robert J Lederman; Ozgur Kocaturk
Journal:  J Magn Reson Imaging       Date:  2011-11-29       Impact factor: 4.813

9.  Virtual dye angiography: flow visualization for MRI-guided interventions.

Authors:  Ashvin K George; Anthony Z Faranesh; Kanishka Ratnayaka; J Andrew Derbyshire; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

10.  Physiological Recording in the MRI Environment (PRiME): MRI-Compatible Hemodynamic Recording System.

Authors:  John W Kakareka; Anthony Z Faranesh; Randall H Pursley; Adrienne Campbell-Washburn; Daniel A Herzka; Toby Rogers; Josh Kanter; Kanishka Ratnayaka; Robert J Lederman; Thomas J Pohida
Journal:  IEEE J Transl Eng Health Med       Date:  2018-03-01       Impact factor: 3.316

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.