Literature DB >> 15908156

Interventional and intraoperative MRI at low field scanner--a review.

Roberto T Blanco1, Risto Ojala, Juho Kariniemi, Jukka Perälä, Jaakko Niinimäki, Osmo Tervonen.   

Abstract

Magnetic resonance imaging (MRI) is a cutting edge imaging modality in detecting diseases and pathologic tissue. The superior soft tissue contrast in MRI allows better definition of the pathology. MRI is increasingly used for guiding, monitoring and controlling percutaneous procedures and surgery. The rapid development of interventional techniques in radiology has led to integration of imaging with computers, new therapy devices and operating room like conditions. This has projected as faster and more accurate imaging and hence more demanding procedures have been applied to the repertoire of the interventional radiologist. In combining features of various other imaging modalities and adding some more into them, interventional MRI (IMRI) has potential to take further the interventional radiology techniques, minimally invasive therapies and surgery. The term "Interventional MRI" consists in short all those procedures, which are performed under MRI guidance. These procedures can be either percutaneous or open surgical of nature. One of the limiting factors in implementing MRI as guidance modality for interventional procedures has been the fact, that most widely used magnet design, a cylindrical magnet, is not ideal for guiding procedures as it does not allow direct access to the patient. Open, low field scanners usually operating around 0.2 T, offer this feature. Clumsy hardware, bad patient access, slow image update frequency and strong magnetic fields have been other limiting factors for interventional MRI. However, the advantages of MRI as an imaging modality have been so obvious that considerable development has taken place in the 20-year history of MRI. The image quality has become better, ever faster software, new innovative sequences, better MRI hardware and increased computing power have accelerated imaging speed and image quality to a totally new level. Perhaps the most important feature in the recent development has been the introduction of open configuration low field MRI devices in the early 1990s; this enabled direct patient access and utilization of the MRI as an interventional device. This article reviews the current status of interventional and intraoperative MRI with special emphasis in low field surrounding.

Entities:  

Mesh:

Year:  2005        PMID: 15908156     DOI: 10.1016/j.ejrad.2005.03.033

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  16 in total

Review 1.  Imaging findings of Pott's disease.

Authors:  Antonio Rivas-Garcia; Silvana Sarria-Estrada; Carme Torrents-Odin; Lourdes Casas-Gomila; Elisa Franquet
Journal:  Eur Spine J       Date:  2012-06-09       Impact factor: 3.134

2.  Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

Authors:  Elliot R McVeigh; Michael A Guttman; Robert J Lederman; Ming Li; Ozgur Kocaturk; Timothy Hunt; Shawn Kozlov; Keith A Horvath
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

3.  The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.

Authors:  Patrick C McDaniel; Clarissa Zimmerman Cooley; Jason P Stockmann; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

Review 4.  MRI-guided laparoscopic and robotic surgery for malignancies.

Authors:  Makoto Hashizume
Journal:  Int J Clin Oncol       Date:  2007-04-27       Impact factor: 3.402

5.  Microtesla MRI of the human brain combined with MEG.

Authors:  Vadim S Zotev; Andrei N Matlashov; Petr L Volegov; Igor M Savukov; Michelle A Espy; John C Mosher; John J Gomez; Robert H Kraus
Journal:  J Magn Reson       Date:  2008-06-21       Impact factor: 2.229

6.  Combined magnetic resonance imaging and optical surgical navigation system guidance of percutaneous liver cryoablation in a porcine model.

Authors:  Kang Zhou; Zhuoli Zhang; Matteo Figini; Junjie Shangguan; Yining Wang; Haifeng Shi; Yumei Li; Zhengyu Jin; Jie Pan
Journal:  Am J Transl Res       Date:  2018-05-15       Impact factor: 4.060

7.  Image-guided laparoscopic surgery in an open MRI operating theater.

Authors:  Norifumi Tsutsumi; Morimasa Tomikawa; Munenori Uemura; Tomohiko Akahoshi; Yoshihiro Nagao; Kozo Konishi; Satoshi Ieiri; Jaesung Hong; Yoshihiko Maehara; Makoto Hashizume
Journal:  Surg Endosc       Date:  2013-01-26       Impact factor: 4.584

8.  Image-guided drug delivery in lung cancer.

Authors:  Timothy S Wiedmann; Tanmoy Sadhukha; Bruce E Hammer; Jayanth Panyam
Journal:  Drug Deliv Transl Res       Date:  2012-02       Impact factor: 4.617

9.  Comparing the signal enhancement of a gadolinium based and an iron-oxide based contrast agent in low-field MRI.

Authors:  Jordy K van Zandwijk; Frank F J Simonis; Friso G Heslinga; Elfi I S Hofmeijer; Robert H Geelkerken; Bennie Ten Haken
Journal:  PLoS One       Date:  2021-08-17       Impact factor: 3.240

10.  Tumor ablation therapy of liver cancers with an open magnetic resonance imaging-based navigation system.

Authors:  Takashi Maeda; Jaesung Hong; Kozo Konishi; Takanori Nakatsuji; Takefumi Yasunaga; Yo-ichi Yamashita; Akinobu Taketomi; Kazuhiro Kotoh; Munechika Enjoji; Hideaki Nakashima; Kazuo Tanoue; Yoshihiko Maehara; Makoto Hashizume
Journal:  Surg Endosc       Date:  2008-09-24       Impact factor: 4.584

View more