Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.

Toshinosuke Akutsu1, Ryota Imai, Jun Saito, Tomoyuki Suzuki.   

Abstract

The Jyros (JR) valve and the newer On-X and MIRA valves, all installed antianatomically, were compared with the St. Jude Medical (SJM) valve in the mitral position to study the effects of valve design differences on the down-stream flow field and the associated valve closing sound. The dynamic particle image velocimetry method utilizing a high-speed video flow visualization technique was used to map the velocity field, and wavelet analysis of the sound was used to find the correlation between the ventricular flow field and the valve closing sound. Based on the experimental data, the following general conclusions can be made. In the velocity field directly below the mitral valve, where the distinct characteristic differences of the valve designs will be evident, twin symmetrical circulations were observed due to the divergent nature of the flow generated by the two inclined half-disks with the valve installed in the anti-anatomical orientation; the SJM, the On-X, and the MIRA valves generated a centrally downward circulation that opposed the valve leaflet closing movement, and resulted in relatively loud valve closing sounds.

Mesh:

Year:  2008        PMID: 18604611     DOI: 10.1007/s10047-008-0411-x

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  6 in total

1.  Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis.

Authors:  Toshinosuke Akutsu; Takashi Masuda
Journal:  J Artif Organs       Date:  2003       Impact factor: 1.731

2.  Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Takamasa Fukuda
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

3.  Effect of the flow field of mechanical bileaflet mitral prostheses on valve closing.

Authors:  Toshinosuke Akutsu; Ryota Imai; Yuuki Deguchi
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

4.  Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Jun Saito
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

5.  Wavelet analysis of bileaflet mechanical valve sounds.

Authors:  Hiroshi Sugiki; Norihiko Shiiya; Toshifumi Murashita; Takashi Kunihara; Kenji Matsuzaki; Takehiro Kubota; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2007-03-23       Impact factor: 1.731

6.  Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

Authors:  T Akutsu; V J Modi
Journal:  Artif Organs       Date:  1997-10       Impact factor: 3.094

  6 in total
  1 in total

Review 1.  Journal of Artificial Organs 2008: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; M Nishimura; T Nishimura; Y Tomizawa; T Yamaoka; H Watanabe
Journal:  J Artif Organs       Date:  2009-03-29       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.