Literature DB >> 8327678

Compression of the left brachiocephalic vein: cause of high signal intensity of the left sigmoid sinus and internal jugular vein on MR images.

T Tanaka1, K Uemura, M Takahashi, S Takehara, T Fukaya, T Tokuyama, A Satoh, H Ryu.   

Abstract

To study the asymmetry in signal intensity of the sigmoid sinuses, internal jugular veins (IJVs), or both sets of structures on magnetic resonance (MR) images, the authors reviewed 226 serial sets of routine MR imaging studies. Cerebral digital subtraction angiography was performed in 20 patients with a markedly higher intensity and/or enhancement on the left; 15 of them also underwent venography. With every sequence, the left sigmoid sinus, IJV, or both were higher in signal intensity significantly more often than the right (range, P = .0001 to .0129). Angiography revealed hemostasis in the left IJV in 16 patients that disappeared during full inspiration in 14. In 13, venography revealed that the left brachiocephalic vein was compressed to occlusion between the aortic arch and the sternum during tidal volume ventilation. The occlusion disappeared at full inspiration, when the distance between the aortic arch and the sternum increased. This hemostasis could be the major cause of the frequent increased signal intensity of the left sigmoid sinus and IJV on MR images.

Entities:  

Mesh:

Year:  1993        PMID: 8327678     DOI: 10.1148/radiology.188.2.8327678

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  19 in total

1.  Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.

Authors:  Hiromasa Suzuki; Hidekazu Oshima; Norio Shiraki; Chisa Ikeya; Yuta Shibamoto
Journal:  Eur Radiol       Date:  2004-08-12       Impact factor: 5.315

2.  Physiologic change in flow velocity and direction of dural venous sinuses with respiration: MR venography and flow analysis.

Authors:  Kohsuke Kudo; Satoshi Terae; Aki Ishii; Tokuhiko Omatsu; Takeshi Asano; Khin Khin Tha; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

3.  Suboptimal contrast opacification of dynamic head and neck MR angiography due to venous stasis and reflux: technical considerations for optimization.

Authors:  D R Hingwala; B Thomas; C Kesavadas; T R Kapilamoorthy
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-02       Impact factor: 3.825

4.  Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Authors:  Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim
Journal:  Neuroradiology       Date:  2006-09-15       Impact factor: 2.804

5.  Value of MR venography for detection of internal jugular vein anomalies in multiple sclerosis: a pilot longitudinal study.

Authors:  R Zivadinov; R Galeotti; D Hojnacki; E Menegatti; M G Dwyer; C Schirda; A M Malagoni; K Marr; C Kennedy; I Bartolomei; C Magnano; F Salvi; B Weinstock-Guttman; P Zamboni
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-07       Impact factor: 3.825

6.  Obstruction of Venous Drainage Linked to Transient Global Amnesia.

Authors:  Ke Han; A-Ching Chao; Feng-Chi Chang; Chih-Ping Chung; Hung-Yi Hsu; Wen-Yung Sheng; Jiang Wu; Han-Hwa Hu
Journal:  PLoS One       Date:  2015-07-14       Impact factor: 3.240

7.  Normal flow signal of the pterygoid plexus on 3T MRA in patients without DAVF of the cavernous sinus.

Authors:  K Watanabe; S Kakeda; R Watanabe; N Ohnari; Y Korogi
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-28       Impact factor: 3.825

8.  Retrograde flow in the dural sinuses detected by three-dimensional time-of-flight MR angiography.

Authors:  Akira Uchino; Keita Nomiyama; Yukinori Takase; Takahiko Nakazono; Yukiko Tominaga; Takeshi Imaizumi; Sho Kudo
Journal:  Neuroradiology       Date:  2006-12-16       Impact factor: 2.804

9.  A comparative study of magnetic resonance venography techniques for the evaluation of the internal jugular veins in multiple sclerosis patients.

Authors:  M Tamizur Rahman; Sean K Sethi; David T Utriainen; J Joseph Hewett; E Mark Haacke
Journal:  Magn Reson Imaging       Date:  2013-07-12       Impact factor: 2.546

10.  Reflux venous flow in dural sinus and internal jugular vein on 3D time-of-flight MR angiography.

Authors:  Jinhee Jang; Bum-Soo Kim; Bom-Yi Kim; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Jae Young Byun
Journal:  Neuroradiology       Date:  2013-07-19       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.