Literature DB >> 16953048

Whole-body voxel phantoms of paediatric patients--UF Series B.

Choonik Lee1, Choonsik Lee, Jonathan L Williams, Wesley E Bolch.   

Abstract

Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm x 0.86 mm x 3.0 mm, 0.90 mm x 0.90 mm x 5.0 mm, 1.16 mm x 1.16 mm x 6.0 mm, 0.94 mm x 0.94 mm x 6.00 mm and 1.18 mm x 1.18 mm x 6.72 mm, respectively.

Entities:  

Mesh:

Year:  2006        PMID: 16953048     DOI: 10.1088/0031-9155/51/18/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Pediatric organ dose measurements in axial and helical multislice CT.

Authors:  Alanna McDermott; R Allen White; Mike Mc-Nitt-Gray; Erin Angel; Dianna Cody
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

Review 2.  Task-based measures of image quality and their relation to radiation dose and patient risk.

Authors:  Harrison H Barrett; Kyle J Myers; Christoph Hoeschen; Matthew A Kupinski; Mark P Little
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

3.  Monte Carlo simulations of adult and pediatric computed tomography exams: validation studies of organ doses with physical phantoms.

Authors:  Daniel J Long; Choonsik Lee; Christopher Tien; Ryan Fisher; Matthew R Hoerner; David Hintenlang; Wesley E Bolch
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

4.  A set of 4D pediatric XCAT reference phantoms for multimodality research.

Authors:  Hannah Norris; Yakun Zhang; Jason Bond; Gregory M Sturgeon; Anum Minhas; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei; W P Segars
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

Review 5.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

6.  The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms.

Authors:  Pooyan Sahbaee; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-01-13       Impact factor: 11.105

7.  Patient-specific radiation dose and cancer risk estimation in CT: part I. development and validation of a Monte Carlo program.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Greta Toncheva; Terry T Yoshizumi; Donald P Frush
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

8.  Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Greta Toncheva; Terry T Yoshizumi; Donald P Frush
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

9.  The UF family of reference hybrid phantoms for computational radiation dosimetry.

Authors:  Choonsik Lee; Daniel Lodwick; Jorge Hurtado; Deanna Pafundi; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

Review 10.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609