Literature DB >> 16948660

Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.

N M Grande1, G Plotino, R Pecci, R Bedini, V A Malagnino, F Somma.   

Abstract

AIM: To determine how instrument design affects the fatigue life of two nickel-titanium (Ni-Ti) rotary systems (Mtwo and ProTaper) under cyclic fatigue stress in simulated root canals.
METHODOLOGY: Cyclic fatigue testing of instruments was performed in stainless steel artificial canals with radii of curvature of 2 or 5 mm and an angle of curvature of 60 degrees . A total of 260 instruments were rotated until fracture occurred and the number of cycles to failure were recorded. The morphology of Ni-Ti rotary instruments was investigated by measuring the volume of millimetre slices of each instrument size starting from the tip to the shank by means of microCT analysis. The fracture surface of three representative samples of each size was analysed by scanning electron microscopy (SEM). Data were analysed by one-way anova, Holm t-test, paired t-test and linear regression; the significance was determined at the 95% confidence level.
RESULTS: Cycles to failure significantly decreased as the instrument volume increased for both the radii of curvature tested (P < 0.01). The radius of curvature had a statistically significant influence on the fatigue life of the instruments (P < 0.05). Larger instruments underwent fracture in less time under cyclic stress than smaller ones. SEM evaluation showed typical features of fracture through fatigue failure.
CONCLUSIONS: The metal volume in the point of maximum stress during a cyclic fatigue test could affect the fatigue life of Ni-Ti rotary instruments. The larger the metal volume, the lower the fatigue resistance.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16948660     DOI: 10.1111/j.1365-2591.2006.01143.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  35 in total

1.  Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.

Authors:  Marie-Chantal Avoaka; Youssef Haïkel
Journal:  Bosn J Basic Med Sci       Date:  2010-05       Impact factor: 3.363

2.  Cyclic fatigue of instruments for endodontic glide path.

Authors:  Gianluca Gambarini; Gianluca Plotino; GianPaolo Sannino; Nicola Maria Grande; Alessio Giansiracusa; Lucila Piasecki; Ulisses Xavier da Silva Neto; Dina Al-Sudani; Luca Testarelli
Journal:  Odontology       Date:  2013-11-07       Impact factor: 2.634

3.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

4.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

5.  Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals.

Authors:  Taha Özyürek; Mustafa Gündoğar; Gülşah Uslu; Koray Yılmaz; Simone Staffoli; Grande Nm; Gianluca Plotino; Antonella Polimeni
Journal:  Odontology       Date:  2018-01-30       Impact factor: 2.634

6.  Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties.

Authors:  Mehmet Emin Kaval; Ismail Davut Capar; Hüseyin Ertas; Bilge Hakan Sen
Journal:  Clin Oral Investig       Date:  2016-07-26       Impact factor: 3.573

7.  Highly concentrated EDTA gel improves cleaning efficiency of root canal preparation in vitro.

Authors:  P Putzer; L Hoy; H Günay
Journal:  Clin Oral Investig       Date:  2008-04-16       Impact factor: 3.573

8.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

9.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01

10.  Cyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators--an in vivo and in vitro study.

Authors:  Gianluca Plotino; Dina Al-Sudani; Stefano Pulino; Nicola M Grande; Piero Alessandro Marcoli; Silvia Pizzi; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2012-06
View more