Literature DB >> 20696596

Calibration function for the Orbitrap FTMS accounting for the space charge effect.

Mikhail V Gorshkov1, David M Good, Yaroslav Lyutvinskiy, Hongqian Yang, Roman A Zubarev.   

Abstract

Ion storage in an electrostatic trap has been implemented with the introduction of the Orbitrap Fourier transform mass spectrometer (FTMS), which demonstrates performance similar to high-field ion cyclotron resonance MS. High mass spectral characteristics resulted in rapid acceptance of the Orbitrap FTMS for Life Sciences applications. The basics of Orbitrap operation are well documented; however, like in any ion trap MS technology, its performance is limited by interactions between the ion clouds. These interactions result in ion cloud couplings, systematic errors in measured masses, interference between ion clouds of different size yet with close m/z ratios, etc. In this work, we have characterized the space-charge effect on the measured frequency for the Orbitrap FTMS, looking for the possibility to achieve sub-ppm levels of mass measurement accuracy (MMA) for peptides in a wide range of total ion population. As a result of this characterization, we proposed an m/z calibration law for the Orbitrap FTMS that accounts for the total ion population present in the trap during a data acquisition event. Using this law, we were able to achieve a zero-space charge MMA limit of 80 ppb for the commercial Orbitrap FTMS system and sub-ppm level of MMA over a wide range of total ion populations with the automatic gain control values varying from 10 to 10(7).
Copyright © 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2010        PMID: 20696596     DOI: 10.1016/j.jasms.2010.06.021

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  21 in total

1.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis

Authors: 
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Utility of accurate mass tags for proteome-wide protein identification.

Authors:  T P Conrads; G A Anderson; T D Veenstra; L Pasa-Tolić; R D Smith
Journal:  Anal Chem       Date:  2000-07-15       Impact factor: 6.986

3.  Mass measurement errors caused by 'local" frequency perturbations in FTICR mass spectrometry.

Authors:  Christophe Masselon; Aleksey V Tolmachev; Gordon A Anderson; Richard Harkewicz; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-01       Impact factor: 3.109

4.  De novo sequencing, peptide composition analysis, and composition-based sequencing: a new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Bernhard Spengler
Journal:  J Am Soc Mass Spectrom       Date:  2004-05       Impact factor: 3.109

5.  Theoretical and experimental prospects for protein identification based solely on accurate mass measurement.

Authors:  Fei He; Mark R Emmett; Kristina Håkansson; Christopher L Hendrickson; Alan G Marshall
Journal:  J Proteome Res       Date:  2004 Jan-Feb       Impact factor: 4.466

6.  Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Authors:  Alexander Makarov; Eduard Denisov; Oliver Lange; Stevan Horning
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

7.  Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-08-24       Impact factor: 3.109

8.  Increasing the mass accuracy of high-resolution LC-MS data using background ions: a case study on the LTQ-Orbitrap.

Authors:  Richard A Scheltema; Anas Kamleh; David Wildridge; Charles Ebikeme; David G Watson; Michael P Barrett; Ritsert C Jansen; Rainer Breitling
Journal:  Proteomics       Date:  2008-11       Impact factor: 3.984

9.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

10.  Statistical evaluation of internal and external mass calibration laws utilized in fourier transform ion cyclotron resonance mass spectrometry.

Authors:  David C Muddiman; Ann L Oberg
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

View more
  8 in total

1.  Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: simulation approach.

Authors:  Andriy Kharchenko; Gleb Vladimirov; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2012-02-22       Impact factor: 3.109

2.  The chromatographic role in high resolution mass spectrometry for non-targeted analysis.

Authors:  Timothy R Croley; Kevin D White; John H Callahan; Steven M Musser
Journal:  J Am Soc Mass Spectrom       Date:  2012-06-19       Impact factor: 3.109

3.  Advanced mass calibration and visualization for FT-ICR mass spectrometry imaging.

Authors:  Donald F Smith; Andriy Kharchenko; Marco Konijnenburg; Ivo Klinkert; Ljiljana Paša-Tolić; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-28       Impact factor: 3.109

4.  Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-08       Impact factor: 3.109

Review 5.  High-Resolution Native Mass Spectrometry.

Authors:  Sem Tamara; Maurits A den Boer; Albert J R Heck
Journal:  Chem Rev       Date:  2021-08-20       Impact factor: 72.087

6.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

7.  MSIWarp: A General Approach to Mass Alignment in Mass Spectrometry Imaging.

Authors:  Jonatan O Eriksson; Alejandro Sánchez Brotons; Melinda Rezeli; Frank Suits; György Markó-Varga; Peter Horvatovich
Journal:  Anal Chem       Date:  2020-12-02       Impact factor: 6.986

8.  Reproducible ion-current-based approach for 24-plex comparison of the tissue proteomes of hibernating versus normal myocardium in swine models.

Authors:  Jun Qu; Rebeccah Young; Brian J Page; Xiaomeng Shen; Nazneen Tata; Jun Li; Xiaotao Duan; James A Fallavollita; John M Canty
Journal:  J Proteome Res       Date:  2014-04-04       Impact factor: 4.466

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.