Literature DB >> 16884940

Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform).

Bruno Sorcini1, Aris Tilikidis.   

Abstract

Image-guided radiation therapy (IGRT) can be used to measure and correct positional errors for target and critical structures immediately prior to or during treatment delivery. Some of the most recent available methods applied for target localization are: transabdominal ultrasound, implanted markers with in room MV or kV X-rays, optical surface tracking systems, implantable electromagnetic markers, in room CT such as kVCT on rail, kilovoltage or megavoltage cone-beam CT (CBCT) and helical megavoltage CT. The verification of the accurate treatment position in conjunction with detailed anatomical information before every fraction can be essential for the outcome of the treatment. In this paper we present the on-board imager (OBI, Varian Medical Systems, Palo Alto, CA) that has been in routine clinical use at the Karolinska University Hospital since June 2004. The OBI has been used for on-line set-up correction of prostate patients using internal gold markers. Displacements of these markers can be monitored radiographically during the treatment course and the registered marker shifts act as a surrogate for prostate motion. For this purpose, on-board kV-kV seems to be an ideal system in terms of image quality. The CBCT function of OBI was installed in March 2005 at our department. It focuses on localizing tumors based on internal anatomy, not just on the conventional external marks or tattoos. The CBCT system provides the capacity for soft tissue imaging in the treatment position and real-time radiographic monitoring during treatment delivery.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16884940     DOI: 10.1016/j.canrad.2006.05.012

Source DB:  PubMed          Journal:  Cancer Radiother        ISSN: 1278-3218            Impact factor:   1.018


  25 in total

1.  Consideration of the likely benefit from implementation of prostate image-guided radiotherapy using current margin sizes: a radiobiological analysis.

Authors:  G S J Tudor; Y L Rimmer; T B Nguyen; M A Cowen; S J Thomas
Journal:  Br J Radiol       Date:  2012-02-14       Impact factor: 3.039

2.  Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems.

Authors:  Weihua Mao; Louis Lee; Lei Xing
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

3.  Theoretical aspects of implementation of kilovoltage cone-beam CT onboard linear accelerator for image-guided radiotherapy.

Authors:  Marta Rodríguez Cordón; Carlos Ferrer Albiach
Journal:  Clin Transl Oncol       Date:  2009-08       Impact factor: 3.405

4.  Synthetic CT generation from CBCT images via deep learning.

Authors:  Liyuan Chen; Xiao Liang; Chenyang Shen; Steve Jiang; Jing Wang
Journal:  Med Phys       Date:  2020-01-13       Impact factor: 4.071

5.  Verification of the dose attenuation of a newly developed vacuum cushion for intensity-modulated radiation therapy of prostate cancer.

Authors:  Toru Takakura; Yoshiyuki Ito; Akinori Higashikawa; Tomohiro Nishiyama; Takashi Sakamoto
Journal:  Radiol Phys Technol       Date:  2016-06-03

Review 6.  Anatomic, functional and molecular imaging in lung cancer precision radiation therapy: treatment response assessment and radiation therapy personalization.

Authors:  Michael MacManus; Sarah Everitt; Tanja Schimek-Jasch; X Allen Li; Ursula Nestle; Feng-Ming Spring Kong
Journal:  Transl Lung Cancer Res       Date:  2017-12

7.  Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis.

Authors:  Clifton D Fuller; Todd J Scarbrough; Jan-Jakob Sonke; Coen R N Rasch; Mehee Choi; Joe Y Ting; Samuel J Wang; Niko Papanikolaou; David I Rosenthal
Journal:  Phys Med Biol       Date:  2009-11-24       Impact factor: 3.609

8.  Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography.

Authors:  Xavier J Juan-Senabre; Carlos Ferrer-Albiach; Marta Rodríguez-Cordón; Agustín Santos-Serra; Juan López-Tarjuelo; Salvador Calzada-Feliu
Journal:  Clin Transl Oncol       Date:  2009-04       Impact factor: 3.405

9.  Clinical evaluation of positioning verification using digital tomosynthesis and bony anatomy and soft tissues for prostate image-guided radiotherapy.

Authors:  Sua Yoo; Q Jackie Wu; Devon Godfrey; Hui Yan; Lei Ren; Shiva Das; William R Lee; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-01       Impact factor: 7.038

10.  Dose perturbations from implanted helical gold markers in proton therapy of prostate cancer.

Authors:  Annelise Giebeler; Jonas Fontenot; Peter Balter; George Ciangaru; Ronald Zhu; Wayne Newhauser
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.