Literature DB >> 19380304

Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography.

Xavier J Juan-Senabre1, Carlos Ferrer-Albiach, Marta Rodríguez-Cordón, Agustín Santos-Serra, Juan López-Tarjuelo, Salvador Calzada-Feliu.   

Abstract

We present a clinical case of a patient diagnosed with a retroperitoneal sarcoma, which received preoperative treatment with daily verification via computed tomography obtained with kilovoltage cone beam. We compare the benefit of this treatment compared to other conventional treatment without image guiding, reporting quantitative results.

Entities:  

Mesh:

Year:  2009        PMID: 19380304     DOI: 10.1007/s12094-009-0349-3

Source DB:  PubMed          Journal:  Clin Transl Oncol        ISSN: 1699-048X            Impact factor:   3.405


  8 in total

Review 1.  Managing geometric uncertainty in conformal intensity-modulated radiation therapy.

Authors:  D A Jaffray; D Yan; J W Wong
Journal:  Semin Radiat Oncol       Date:  1999-01       Impact factor: 5.934

2.  Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging.

Authors:  Dirk Verellen; Guy Soete; Nadine Linthout; Swana Van Acker; Patsy De Roover; Vincent Vinh-Hung; Jan Van de Steene; Guy Storme
Journal:  Radiother Oncol       Date:  2003-04       Impact factor: 6.280

Review 3.  Errors and margins in radiotherapy.

Authors:  Marcel van Herk
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

4.  When should systematic patient positioning errors in radiotherapy be corrected?

Authors:  Thomas Bortfeld; Marcel van Herk; Steve B Jiang
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

Review 5.  Emergent technologies for 3-dimensional image-guided radiation delivery.

Authors:  David A Jaffray
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

Review 6.  Optically guided patient positioning techniques.

Authors:  Sanford L Meeks; Wolfgang A Tomé; Tywla R Willoughby; Patrick A Kupelian; Thomas H Wagner; John M Buatti; Francis J Bova
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

7.  Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform).

Authors:  Bruno Sorcini; Aris Tilikidis
Journal:  Cancer Radiother       Date:  2006-08-01       Impact factor: 1.018

8.  A (short) history of image-guided radiotherapy.

Authors:  Dirk Verellen; Mark De Ridder; Guy Storme
Journal:  Radiother Oncol       Date:  2008-01       Impact factor: 6.280

  8 in total
  1 in total

1.  Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours.

Authors:  X J Juan-Senabre; J López-Tarjuelo; A Conde-Moreno; A Santos-Serra; A L Sánchez-Iglesias; J D Quirós-Higueras; N de Marco Blancas; S Calzada-Feliu; C Ferrer-Albiach
Journal:  Clin Transl Oncol       Date:  2011-11       Impact factor: 3.405

  1 in total