Three-dimensional artifact induced by projection weighting and misalignment.

J Hsieh1.   

Abstract

In recent years, the use of computer graphic techniques to produce three-dimensional (3-D) and reformatted images from a set of axial computed tomography (CT) images has gained significant interest. In most cases, the CT images are generated with the projection data set weighted prior to reconstruction, to combat motion artifacts, data inconsistency, or redundant data samples. In this paper, we investigate the potential bias introduced to the reconstruction as a result of the interaction of the projection weights and the isocenter misalignment (ISM). We demonstrate that when the weights applied to the conjugate rays are significantly different, bias will result which favors the sample with a higher weight. Although the error is not easily detected in axial CT images, it can be quite visible in 3-D or multiplanar reformatted (MPR) images. In this paper, we first present a theoretical framework to analyze and predict the bias. The theoretical prediction is validated by both computer simulations and phantom experiments. Several schemes to combat this artifact are subsequently presented; and their effectiveness is demonstrated.

Entities:  

Mesh:

Year:  1999        PMID: 10385294     DOI: 10.1109/42.768846

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  A phantom-based calibration method for digital x-ray tomosynthesis.

Authors:  Hui Miao; Xizeng Wu; Huijuan Zhao; Hong Liu
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

2.  A geometric calibration method for cone beam CT systems.

Authors:  Kai Yang; Alexander L C Kwan; DeWitt F Miller; John M Boone
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

3.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

4.  The effect of varying low-dose protocols on perceived image quality in multidetector CT in a rabbit model of acute appendicitis.

Authors:  Marcus Hörmann; Marcel O Philipp; Heidrun Eberl; Ursula Windberger; Wolfgang Matzek; Cornelia Schäfer-Prokop; Viktor M Metz
Journal:  Eur Radiol       Date:  2004-04-06       Impact factor: 5.315

5.  Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT.

Authors:  Jintao Zhao; Xiaodong Hu; Jing Zou; Xiaotang Hu
Journal:  Sensors (Basel)       Date:  2015-09-09       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.