Estimation of geometrical parameters and collimator evaluation for cone beam tomography.

G T Gullberg1, B M Tsui, C R Crawford, J G Ballard, J T Hagius.   

Abstract

A method is presented for estimating the geometrical parameters for a cone beam detector geometry from the coordinates of the centroid of a projected point source sampled over 360 degrees. Nonlinear expressions are derived for the coordinates of the centroids in terms of the geometrical parameters which include: the two-dimensional coordinates of the projection of the center of rotation onto the detector image plane; the focal length; the distance from the focal point to the center of rotation; and the spatial coordinates of the point source itself. Experimental data were obtained using a rotating gamma camera with a symmetrically converging collimator. The Marquardt algorithm was used to estimate the parameters for this particular cone beam geometry. The method was able to estimate the geometrical parameters and evaluate the accuracy of the collimator construction.

Mesh:

Year:  1990        PMID: 2333053     DOI: 10.1118/1.596505

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  A geometric calibration method for cone beam CT systems.

Authors:  Kai Yang; Alexander L C Kwan; DeWitt F Miller; John M Boone
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

2.  Geometric characterization of multi-axis multi-pinhole SPECT.

Authors:  Frank P DiFilippo
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals.

Authors:  Andrew B Hwang; Benjamin L Franc; Grant T Gullberg; Bruce H Hasegawa
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

4.  A line-source method for aligning on-board and other pinhole SPECT systems.

Authors:  Susu Yan; James Bowsher; Fang-Fang Yin
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

5.  A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation.

Authors:  Jacob A Piatt; Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-16       Impact factor: 1.679

6.  Geometric Calibration and Image Reconstruction for a Segmented Slant-Hole Stationary Cardiac SPECT System.

Authors:  Yanfei Mao; Zhicong Yu; Gengsheng L Zeng
Journal:  J Nucl Med Technol       Date:  2015-05-08

7.  Direct determination of geometric alignment parameters for cone-beam scanners.

Authors:  C Mennessier; R Clackdoyle; F Noo
Journal:  Phys Med Biol       Date:  2009-02-25       Impact factor: 3.609

8.  Multi-Mounted X-Ray Computed Tomography.

Authors:  Jian Fu; Zhenzhong Liu; Jingzheng Wang
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

9.  Multimodality calibration for simultaneous fluoroscopic and nuclear imaging.

Authors:  Casper Beijst; Mattijs Elschot; Sandra van der Velden; Hugo W A M de Jong
Journal:  EJNMMI Phys       Date:  2016-08-30

10.  Analysis and Correction of Dynamic Geometric Misalignment for Nano-Scale Computed Tomography at BSRF.

Authors:  Jian Fu; Chen Li; Zhenzhong Liu
Journal:  PLoS One       Date:  2015-10-28       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.