Literature DB >> 16683113

High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplasty.

A Grose1, A González Della Valle, P Bullough, S Lyman, I Tomek, P Pellicci.   

Abstract

The role of surface finish on the survivorship of cemented femoral stems continues to be debated. A total of 34 proximally roughened cemented stems were implanted in 33 consecutive patients undergoing total hip arthroplasty by a single surgeon. An alarmingly high failure rate was observed, prompting a retrospective chart review, analysis of radiographs, and evaluation of retrieved stems and pathological specimens. Nineteen patients were available with more than two years follow-up. Of these 19 patients, nine stems had failed (47%) due to severe osteolysis and stem loosening. Failures were significantly more common in the male gender (p<0.005), and young (p=0.05), tall (p<0.002), and heavy patients (p<0.004). All failed revised hips showed severe metallosis, with both gross and microscopic evidence of metallic shedding from the stems. Our findings suggest that this proximally roughened stem is susceptible to early failure. Failure is characterized by stem debonding, subsidence within the cement mantle, shedding of metallic and cement particles due to fretting, and rapidly progressive osteolysis. These findings have been observed with other rough surface finish cemented stems.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16683113      PMCID: PMC2532124          DOI: 10.1007/s00264-005-0066-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  31 in total

1.  The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface.

Authors:  N A Ramaniraka; L R Rakotomanana; P F Leyvraz
Journal:  J Bone Joint Surg Br       Date:  2000-03

2.  Thin cement mantle and osteolysis with a precoated stem.

Authors:  K Kawate; T Ohmura; N Hiyoshi; Y Natsume; T Teranishi; S Tamai
Journal:  Clin Orthop Relat Res       Date:  1999-08       Impact factor: 4.176

3.  Should the cement mantle around the femoral component be thick or thin?

Authors:  J A Skinner; S Todo; M Taylor; J S Wang; V Pinskerova; G Scott
Journal:  J Bone Joint Surg Br       Date:  2003-01

4.  The Swedish Total Hip Replacement Register.

Authors:  Henrik Malchau; Peter Herberts; Thomas Eisler; Göran Garellick; Peter Söderman
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

5.  Influence of surface finish in total hip arthroplasty.

Authors:  Bradley K Vaughn; Elizabeth Fuller; Rebekah Peterson; Susan G Capps
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

6.  A prospective randomized trial of cemented femoral components with polished versus grit-blasted surface finish and identical stem geometry.

Authors:  Thomas Parker Vail; Devon Goetz; Michael Tanzer; David A Fisher; Craig G Mohler; John J Callaghan
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

7.  In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: the influence of wear mechanism on clinical outcome.

Authors:  J R Howell; L A Blunt; C Doyle; R M Hooper; A J C Lee; R S M Ling
Journal:  J Arthroplasty       Date:  2004-01       Impact factor: 4.757

8.  Loosening of matt and polished cemented femoral stems.

Authors:  D W Howie; R G Middleton; K Costi
Journal:  J Bone Joint Surg Br       Date:  1998-07

9.  Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry.

Authors:  Dennis K Collis; Craig G Mohler
Journal:  J Bone Joint Surg Am       Date:  2002-04       Impact factor: 5.284

10.  Sixteen-year follow-up of the cemented spectron femoral stem for hip arthroplasty.

Authors:  Paul S Issack; Herman G Botero; Rudi N Hiebert; Matthew R Bong; Steven A Stuchin; Joseph D Zuckerman; Paul E Di Cesare
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

View more
  10 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Authors:  Thomas Kadar; Eva Dybvik; Geir Hallan; Ove Furnes; Leif Ivar Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs.

Authors:  Jonathan Hutt; Alexandra Hazlerigg; Ansari Aneel; Geoffrey Epie; Husam Dabis; Roy Twyman; Andrew Cobb
Journal:  Int Orthop       Date:  2014-01-29       Impact factor: 3.075

4.  Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Adriana Zoppi; Eduardo A Salvati
Journal:  Int Orthop       Date:  2006-03-31       Impact factor: 3.075

5.  A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years.

Authors:  Thomas Kadar; Geir Hallan; Arild Aamodt; Kari Indrekvam; Mona Badawy; Leif Ivar Havelin; Terje Stokke; Kristin Haugan; Birgitte Espehaug; Ove Furnes
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

6.  Implant survival of the most common cemented total hip devices from the Nordic Arthroplasty Register Association database.

Authors:  Mika Junnila; Inari Laaksonen; Antti Eskelinen; Pekka Pulkkinen; Leif Ivar Havelin; Ove Furnes; Anne Marie Fenstad; Alma B Pedersen; Søren Overgaard; Johan Kärrholm; Göran Garellick; Henrik Malchau; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2016-08-23       Impact factor: 3.717

7.  Severe Periprosthetic Metallosis and Polyethylene Liner Failure Complicating Total Hip Replacement: The Cloud Sign.

Authors:  Amir Paydar; Felix S Chew; Paul A Manner
Journal:  Radiol Case Rep       Date:  2015-12-07

8.  Inflammatory tissue reactions around aseptically loose cemented hip prostheses: A retrieval study of the Spectron EF stem with Reflection All-Poly acetabular cup.

Authors:  Susann Wolf; Anne Christine Johannessen; Peter Ellison; Ove Furnes; Geir Hallan; Katharina Rogg; Kathrine Skarstein; Paul Johan Høl
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2022-01-31       Impact factor: 3.405

9.  18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register: concerns about some newer implants.

Authors:  Birgitte Espehaug; Ove Furnes; Lars B Engesaeter; Leif I Havelin
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

10.  Fifteen-year results of precoated femoral stem in primary hybrid total hip arthroplasty.

Authors:  Dong Hun Suh; Ho Hyun Yun; Sung Kwang Chun; Won Yong Shon
Journal:  Clin Orthop Surg       Date:  2013-05-15
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.