Literature DB >> 10755444

The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface.

N A Ramaniraka1, L R Rakotomanana, P F Leyvraz.   

Abstract

After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10755444     DOI: 10.1302/0301-620x.82b2 .9613

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  22 in total

1.  Static shear strength between polished stem and seven commercial acrylic bone cements.

Authors:  Hongyu Zhang; Leigh Brown; Liam Blunt
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

2.  Applications of finite element simulation in orthopedic and trauma surgery.

Authors:  Antonio Herrera; Elena Ibarz; José Cegoñino; Antonio Lobo-Escolar; Sergio Puértolas; Enrique López; Jesús Mateo; Luis Gracia
Journal:  World J Orthop       Date:  2012-04-18

Review 3.  Bisphosphonate-based strategies for bone tissue engineering and orthopedic implants.

Authors:  Juan Pablo Cattalini; Aldo R Boccaccini; Silvia Lucangioli; Viviana Mouriño
Journal:  Tissue Eng Part B Rev       Date:  2012-05-14       Impact factor: 6.389

4.  Stretchable heterogeneous composites with extreme mechanical gradients.

Authors:  Rafael Libanori; Randall M Erb; Alain Reiser; Hortense Le Ferrand; Martin J Süess; Ralph Spolenak; André R Studart
Journal:  Nat Commun       Date:  2012       Impact factor: 14.919

5.  High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplasty.

Authors:  A Grose; A González Della Valle; P Bullough; S Lyman; I Tomek; P Pellicci
Journal:  Int Orthop       Date:  2006-04-29       Impact factor: 3.075

6.  Multi-patient finite element simulation of keeled versus pegged glenoid implant designs in shoulder arthroplasty.

Authors:  Werner Pomwenger; Karl Entacher; Herbert Resch; Peter Schuller-Götzburg
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

7.  Peri-implant stress correlates with bone and cement morphology: Micro-FE modeling of implanted cadaveric glenoids.

Authors:  Hwabok Wee; April D Armstrong; Wesley W Flint; Allen R Kunselman; Gregory S Lewis
Journal:  J Orthop Res       Date:  2015-06-18       Impact factor: 3.494

8.  Hybrid total hip arthroplasty using specifically-designed stems for patients with developmental dysplasia of the hip. A minimum five-year follow-up study.

Authors:  Hiroshi Ito; Hiromasa Tanino; Yasuhiro Yamanaka; Toshiki Nakamura; Takeo Matsuno
Journal:  Int Orthop       Date:  2010-07-24       Impact factor: 3.075

9.  Micro and nano MgO particles for the improvement of fracture toughness of bone-cement interfaces.

Authors:  Morshed Khandaker; Yanling Li; Tracy Morris
Journal:  J Biomech       Date:  2013-01-16       Impact factor: 2.712

10.  Fixation of the cemented stem: clinical relevance of the porosity and thickness of the cement mantle.

Authors:  Philippe Hernigou; Gildasio Daltro; Charles Henri Flouzat Lachaniette; Xavier Roussignol; Martin Mukisi Mukasa; Alexandre Poignard
Journal:  Open Orthop J       Date:  2009-02-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.