Literature DB >> 16575608

Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty.

Alejandro González Della Valle1, Fernando Comba, Adriana Zoppi, Eduardo A Salvati.   

Abstract

We evaluated the mid-term clinical and radiographical performance of a cohort of patients who underwent primary total hip replacement with a modern, forged cobalt-chrome, polished cemented femoral stem with proximal and distal centralisation. Sixty-seven patients with 73 hybrid total hip replacements were followed up clinically and radiographically for an average of 6.1 years (4-8.5). No patient was lost. No hips required revision, and all stems are radiographically well-fixed. Four hips developed localised osteolysis: one at the site of a proximal periprosthetic fracture, another at the level of a lateral femoral window of a previous core decompression, the third at the mid third of the femoral component, and the fourth on the greater trochanter, associated with accelerated polyethylene wear. This modern polished stem yielded excellent, predictable clinical and radiographic results at an intermediate follow-up.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16575608      PMCID: PMC3172773          DOI: 10.1007/s00264-006-0077-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  40 in total

1.  Charnley low-frictional torque arthroplasty of the hip. 20-to-30 year results.

Authors:  B M Wroblewski; P A Fleming; P D Siney
Journal:  J Bone Joint Surg Br       Date:  1999-05

2.  The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips.

Authors:  H D W Williams; G Browne; G A Gie; R S M Ling; A J Timperley; N A Wendover
Journal:  J Bone Joint Surg Br       Date:  2002-04

3.  High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplasty.

Authors:  A Grose; A González Della Valle; P Bullough; S Lyman; I Tomek; P Pellicci
Journal:  Int Orthop       Date:  2006-04-29       Impact factor: 3.075

4.  Collarless polished tapered stem: clinical and radiological follow-up over 5 years.

Authors:  Piers Yates; Dietmar Gobel; Gordon Bannister
Journal:  J Arthroplasty       Date:  2002-02       Impact factor: 4.757

5.  Early failure of precoated femoral components in primary total hip arthroplasty.

Authors:  Alvin Ong; Kirk L Wong; Max Lai; Jonathan P Garino; Marvin E Steinberg
Journal:  J Bone Joint Surg Am       Date:  2002-05       Impact factor: 5.284

6.  Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience.

Authors:  B M Wroblewski; P D Siney; P A Fleming
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

7.  Early failure of a roughened surface, precoated femoral component in total hip arthroplasty.

Authors:  G M Sylvain; S Kassab; R Coutts; R Santore
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

8.  Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components.

Authors:  Daniel J Berry; W Scott Harmsen; Miguel E Cabanela; Bernard F Morrey
Journal:  J Bone Joint Surg Am       Date:  2002-02       Impact factor: 5.284

9.  Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up.

Authors:  J J Callaghan; J C Albright; D D Goetz; J P Olejniczak; R C Johnston
Journal:  J Bone Joint Surg Am       Date:  2000-04       Impact factor: 5.284

10.  Staged bilateral total hip arthroplasty using rough and smooth surface femoral stems with similar design: 10-year survivorship of 48 cases.

Authors:  Sandeep P Datir; Charles H Wynn-Jones
Journal:  Acta Orthop       Date:  2005-12       Impact factor: 3.717

View more
  2 in total

1.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

2.  The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs.

Authors:  Jonathan Hutt; Alexandra Hazlerigg; Ansari Aneel; Geoffrey Epie; Husam Dabis; Roy Twyman; Andrew Cobb
Journal:  Int Orthop       Date:  2014-01-29       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.