Literature DB >> 16611772

Intracranial time-resolved contrast-enhanced MR angiography at 3T.

T A Cashen1, J C Carr, W Shin, M T Walker, S F Futterer, A Shaibani, R M McCarthy, T J Carroll.   

Abstract

BACKGROUND AND
PURPOSE: A method is presented for high-temporal-resolution MR angiography (MRA) using a combination of undersampling strategies and a high-field (3T) scanner. Currently, the evaluation of cerebrovascular disorders involving arteriovenous shunting or retrograde flow is accomplished with conventional radiographic digital subtraction angiography, because of its high spatial and temporal resolutions. Multiphase MRA could potentially provide the same diagnostic information noninvasively, though this is technically challenging because of the inherent trade-off between signal intensity-to-noise ratio (S/N), spatial resolution, and temporal resolution in MR imaging.
METHODS: Numerical simulations addressed the choice of imaging parameters at 3T to maximize S/N and the data acquisition rate while staying within specific absorption rate limits. The increase in S/N at 3T was verified in vivo. An imaging protocol was developed with S/N, spatial resolution, and temporal resolution suitable for intracranial angiography. Partial Fourier imaging, parallel imaging, and the time-resolved echo-shared acquisition technique (TREAT) were all used to achieve sufficient undersampling.
RESULTS: In 40 volunteers and 10 patients exhibiting arteriovenous malformations or fistulas, intracranial time-resolved contrast-enhanced MRA with high acceleration at high field produced diagnostic-quality images suitable for assessment of pathologies involving arteriovenous shunting or retrograde flow. The technique provided spatial resolution of 1.1 x 1.1 x 2.5 mm and temporal resolution of 2.5 seconds/frame. The combination of several acceleration methods, each with modest acceleration, can provide a high overall acceleration without the artifacts of any one technique becoming too pronounced.
CONCLUSION: By taking advantage of the increased S/N provided by 3T magnets over conventional 1.5T magnets and converting this additional S/N into higher temporal resolution through acceleration strategies, intracranial time-resolved MRA becomes feasible.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16611772      PMCID: PMC8133971     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  25 in total

1.  Partially parallel imaging with localized sensitivities (PILS).

Authors:  M A Griswold; P M Jakob; M Nittka; J W Goldfarb; A Haase
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  High-resolution intracranial and cervical MRA at 3.0T: technical considerations and initial experience.

Authors:  M A Bernstein; J Huston; C Lin; G F Gibbs; J P Felmlee
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

3.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

4.  VD-AUTO-SMASH imaging.

Authors:  R M Heidemann; M A Griswold; A Haase; P M Jakob
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

7.  Time-resolved contrast-enhanced 3D MR angiography.

Authors:  F R Korosec; R Frayne; T M Grist; C A Mistretta
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

8.  Halving MR imaging time by conjugation: demonstration at 3.5 kG.

Authors:  D A Feinberg; J D Hale; J C Watts; L Kaufman; A Mark
Journal:  Radiology       Date:  1986-11       Impact factor: 11.105

9.  The effect of injection rate on time-resolved contrast-enhanced peripheral MRA.

Authors:  T J Carroll; F R Korosec; J S Swan; T F Hany; T M Grist; C A Mistretta
Journal:  J Magn Reson Imaging       Date:  2001-10       Impact factor: 4.813

10.  The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality.

Authors:  J H Maki; M R Prince; F J Londy; T L Chenevert
Journal:  J Magn Reson Imaging       Date:  1996 Jul-Aug       Impact factor: 4.813

View more
  28 in total

1.  Noninvasive evaluation of cerebral arteriovenous malformations by 4D-MRA for preoperative planning and postoperative follow-up in 56 patients: comparison with DSA and intraoperative findings.

Authors:  D R Hadizadeh; G M Kukuk; D T Steck; J Gieseke; H Urbach; H J Tschampa; S Greschus; A Kovàcs; M Möhlenbruch; A Bostroem; H H Schild; W A Willinek
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

2.  Optimized high-resolution contrast-enhanced hepatobiliary imaging at 3 tesla: a cross-over comparison of gadobenate dimeglumine and gadoxetic acid.

Authors:  Alex Frydrychowicz; Scott K Nagle; Sharon L D'Souza; Karl K Vigen; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2011-07-12       Impact factor: 4.813

3.  Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV.

Authors:  Stephen J Riederer; Houchun Harry Hu; David G Kruger; Clifton R Haider; Norbert G Campeau; John Huston
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

4.  4D radial contrast-enhanced MR angiography with sliding subtraction.

Authors:  Ty A Cashen; Hyun Jeong; Maulin K Shah; Hem M Bhatt; Wanyong Shin; James C Carr; Matthew T Walker; H Hunt Batjer; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

5.  Cortical vein thrombosis: the diagnostic value of different imaging modalities.

Authors:  Jennifer Linn; Stefan Michl; Bochmann Katja; Thomas Pfefferkorn; Martin Wiesmann; Sabine Hartz; Martin Dichgans; Hartmut Brückmann
Journal:  Neuroradiology       Date:  2010-01-28       Impact factor: 2.804

Review 6.  A compartment-based approach for the imaging evaluation of tinnitus.

Authors:  S Vattoth; R Shah; J K Curé
Journal:  AJNR Am J Neuroradiol       Date:  2009-09-17       Impact factor: 3.825

7.  Prediction of response to chemoradiation therapy in squamous cell carcinomas of the head and neck using dynamic contrast-enhanced MR imaging.

Authors:  S Kim; L A Loevner; H Quon; A Kilger; E Sherman; G Weinstein; A Chalian; H Poptani
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-01       Impact factor: 3.825

8.  3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction.

Authors:  Y Wu; N Kim; F R Korosec; A Turk; H A Rowley; O Wieben; C A Mistretta; P A Turski
Journal:  AJNR Am J Neuroradiol       Date:  2007-10-10       Impact factor: 3.825

9.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

10.  Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.

Authors:  Sungheon G Kim; Li Feng; Robert Grimm; Melanie Freed; Kai Tobias Block; Daniel K Sodickson; Linda Moy; Ricardo Otazo
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.