Literature DB >> 17928376

3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction.

Y Wu1, N Kim, F R Korosec, A Turk, H A Rowley, O Wieben, C A Mistretta, P A Turski.   

Abstract

HYPR TRICKS is an acquisition method that combines radial k-space trajectories, sampling k-space at different rates (TRICKS), and a new strategy for image reconstruction that uses highly constrained backprojection reconstruction (HYPR). This approach provides 3D time-resolved contrast-enhanced MR angiograms of the cerebral vessels with subsecond frame update times and submillimeter in-plane spatial resolution. Artifacts are suppressed, and signal-to-noise ratio is well maintained, by using HYPR reconstruction.

Mesh:

Substances:

Year:  2007        PMID: 17928376      PMCID: PMC8134257          DOI: 10.3174/ajnr.A0772

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  13 in total

1.  Cerebral dural arteriovenous fistulas: detection by dynamic MR projection angiography.

Authors:  S G Wetzel; D Bilecen; P Lyrer; G Bongartz; E Seifritz; E W Radue; K Scheffler
Journal:  AJR Am J Roentgenol       Date:  2000-05       Impact factor: 3.959

2.  Carotid bifurcation: evaluation of time-resolved three-dimensional contrast-enhanced MR angiography.

Authors:  T J Carroll; F R Korosec; G M Petermann; T M Grist; P A Turski
Journal:  Radiology       Date:  2001-08       Impact factor: 11.105

3.  Clinical applications of 2-D dynamic contrast-enhanced MR subtraction angiography in neurosurgery -- preliminary results.

Authors:  F J Hans; M H Reinges; P Reipke; P Reinacher; T Krings
Journal:  Zentralbl Neurochir       Date:  2005-11

4.  Time-resolved contrast-enhanced 3D MR angiography.

Authors:  F R Korosec; R Frayne; T M Grist; C A Mistretta
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

5.  Brain arteriovenous malformations: measurement of nidal volume using a combination of static and dynamic magnetic resonance angiography techniques.

Authors:  S Nagaraja; D Capener; S C Coley; K J Lee; I D Wilkinson; A A Kemeny; P D Griffiths
Journal:  Neuroradiology       Date:  2005-04-15       Impact factor: 2.804

6.  Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study.

Authors:  Jean-Yves Gauvrit; Xavier Leclerc; Catherine Oppenheim; Thierry Munier; Denis Trystram; Henda Rachdi; François Nataf; Jean-Pierre Pruvo; Jean-François Meder
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

7.  Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography.

Authors:  M Duran; S O Schoenberg; W T C Yuh; M V Knopp; G van Kaick; M Essig
Journal:  Eur Radiol       Date:  2002-06-04       Impact factor: 5.315

8.  Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: initial results.

Authors:  Kambiz Nael; Henrik J Michaely; Pablo Villablanca; Noriko Salamon; Gerhard Laub; J Paul Finn
Journal:  Invest Radiol       Date:  2006-02       Impact factor: 6.016

9.  Brain arteriovenous malformations: assessment with dynamic MR digital subtraction angiography.

Authors:  P D Griffiths; N Hoggard; D J Warren; I D Wilkinson; B Anderson; C A Romanowski
Journal:  AJNR Am J Neuroradiol       Date:  2000 Nov-Dec       Impact factor: 3.825

10.  Intracranial time-resolved contrast-enhanced MR angiography at 3T.

Authors:  T A Cashen; J C Carr; W Shin; M T Walker; S F Futterer; A Shaibani; R M McCarthy; T J Carroll
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

View more
  10 in total

1.  Noninvasive evaluation of cerebral arteriovenous malformations by 4D-MRA for preoperative planning and postoperative follow-up in 56 patients: comparison with DSA and intraoperative findings.

Authors:  D R Hadizadeh; G M Kukuk; D T Steck; J Gieseke; H Urbach; H J Tschampa; S Greschus; A Kovàcs; M Möhlenbruch; A Bostroem; H H Schild; W A Willinek
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

2.  HYPR TOF: time-resolved contrast-enhanced intracranial MR angiography using time-of-flight as the spatial constraint.

Authors:  Yijing Wu; Steven R Kecskemeti; Kevin Johnson; Kang Wang; Howard Rowley; Oliver Wieben; Charles Mistretta; Patrick Turski
Journal:  J Magn Reson Imaging       Date:  2011-02-01       Impact factor: 4.813

3.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

4.  Detection and grading of dAVF: prospects and limitations of 3T MRI.

Authors:  Andrea Bink; Joachim Berkefeld; Marlies Wagner; Se-Jong You; Hanns Ackermann; Matthias W Lorenz; Christian Senft; Richard du Mesnil de Rochemont
Journal:  Eur Radiol       Date:  2011-09-21       Impact factor: 5.315

Review 5.  New Treatment Approaches to Arteriovenous Malformations.

Authors:  Patrick Gilbert; Josée Dubois; Marie France Giroux; Gilles Soulez
Journal:  Semin Intervent Radiol       Date:  2017-09-11       Impact factor: 1.513

Review 6.  Vascular anomalies: what a radiologist needs to know.

Authors:  Josée Dubois; Marianne Alison
Journal:  Pediatr Radiol       Date:  2010-04-30

7.  Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR).

Authors:  Hyun J Jeong; Ty A Cashen; Michael C Hurley; Christopher Eddleman; Christopher Getch; H Hunt Batjer; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

Review 8.  Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.

Authors:  Alice C Yang; Madison Kretzler; Sonja Sudarski; Vikas Gulani; Nicole Seiberlich
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

Review 9.  Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations.

Authors:  Yuriko Suzuki; Noriyuki Fujima; Matthias J P van Osch
Journal:  Magn Reson Med Sci       Date:  2019-11-22       Impact factor: 2.471

Review 10.  Pushing CT and MR imaging to the molecular level for studying the "omics": current challenges and advancements.

Authors:  Hsuan-Ming Huang; Yi-Yu Shih
Journal:  Biomed Res Int       Date:  2014-03-13       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.