Properties of the prototype 256-row (cone beam) CT scanner.

Shinichiro Mori1, Masahiro Endo, Takayuki Obata, Takanori Tsunoo, Kandatsu Susumu, Shuji Tanada.   

Abstract

We evaluated Feldkamp artifacts, which are specific to cone-beam computed tomography (CT), in phantom and clinical studies using the 256-multidetector-row CT (256MDCT), and compared the reconstruction accuracy of axial and helical scans. Image noise, slice sensitivity profile (SSP) and artifacts with the 256MDCT were evaluated using a phantom, and the results were compared to those of a 64MDCT. We also examined chest and abdomen scans produced with the 256MDCT in volunteers. For the axial scan, Feldkamp artifacts were visualized as high-frequency streak-like artifacts that are oriented horizontally at the edge of the scan region in the phantom study. Similar results were obtained with the volunteers in soft-tissue regions near either bony structures or air pockets. Feldkamp artifacts with the 256MDCT can lead to misdiagnosis if not correctly identified and minimized via helical scanning. Image noise was less for axial than helical scans, while SSP was better with helical than axial scans. Feldkamp artifacts observed in the 256MDCT images, however, did not generally affect the interpretation of images. The 256MDCT promises more accurate diagnosis, and will provide volumetric cine images of wider cranio-caudal coverage, enabling new applications of CT.

Mesh:

Year:  2006        PMID: 16568264     DOI: 10.1007/s00330-006-0213-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.

Authors:  M Gies; W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging.

Authors:  Shinichiro Mori; Masahiro Endo; Takanori Tsunoo; Susumu Kandatsu; Shuji Tanada; Hiroshi Aradate; Yasuo Saito; Hiroaki Miyazaki; Kazumasa Satoh; Satoshi Matsushita; Masahiro Kusakabe
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

3.  Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage.

Authors:  Marc Kachelriess; Michael Knaup; Willi A Kalender
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

4.  Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography): a preliminary study with a porcine model.

Authors:  Shinichiro Mori; Chisato Kondo; Naoki Suzuki; Hiroyo Yamashita; Asaki Hattori; Masahiro Kusakabe; Masahiro Endo
Journal:  J Comput Assist Tomogr       Date:  2005 Jan-Feb       Impact factor: 1.826

5.  Clinical potentials of the prototype 256-detector row CT-scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Kenya Murase; Hideaki Fujiwara; Kandatsu Susumu; Shuji Tanada
Journal:  Acad Radiol       Date:  2005-02       Impact factor: 3.173

6.  Volumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model.

Authors:  Shinichiro Mori; Takayuki Obata; Naoshi Nakajima; Nobutsune Ichihara; Masahiro Endo
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

7.  Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography: initial experience.

Authors:  Chisato Kondo; Shinichiro Mori; Masahiro Endo; Kiyoko Kusakabe; Naoki Suzuki; Asaki Hattori; Masahiro Kusakabe
Journal:  J Comput Assist Tomogr       Date:  2005 Sep-Oct       Impact factor: 1.826

8.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

9.  Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-MDCT scanner.

Authors:  Shinichiro Mori; Takayuki Obata; Riwa Kishimoto; Hirotoshi Kato; Kenya Murase; Hideaki Fujiwara; Susumu Kandatsu; Shuji Tanada; Hirohiko Tsujii; Masahiro Endo
Journal:  AJR Am J Roentgenol       Date:  2005-07       Impact factor: 3.959

10.  Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry.

Authors:  Shinichiro Mori; Masahiro Endo; Kanae Nishizawa; Takanori Tsunoo; Takahiko Aoyama; Hideaki Fujiwara; Kenya Murase
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

View more
  9 in total

1.  Image quality and radiation exposure in 320-row temporal bone computed tomography.

Authors:  H C Bauknecht; E Siebert; A Dannenberg; G Bohner; C Jach; S Diekmann; C Scheurig; R Klingebiel
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

2.  Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging.

Authors:  F G Draenert; F Gebhart; M Berthold; M Gosau; W Wagner
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

Review 3.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

Review 4.  Coronary CT angiography: Diagnostic value and clinical challenges.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

5.  Positional dependence of the CT number with use of a cone-beam CT scanner for an electron density phantom in particle beam therapy.

Authors:  Yohsuke Kusano; Saki Uesaka; Kaori Yajima; Motoki Kumagai; Hideyuki Mizuno; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2012-12-16

6.  Unenhanced 320-row multidetector computed tomography of the brain in children: comparison of image quality and radiation dose among wide-volume, one-shot volume, and helical scan modes.

Authors:  Sun Kyung Jeon; Young Hun Choi; Jung-Eun Cheon; Woo Sun Kim; Yeon Jin Cho; Ji Young Ha; Seung Hyun Lee; Hyejin Hyun; In-One Kim
Journal:  Pediatr Radiol       Date:  2018-02-15

Review 7.  CT coronary angiography: 256-slice and 320-detector row scanners.

Authors:  Edward M Hsiao; Frank J Rybicki; Michael Steigner
Journal:  Curr Cardiol Rep       Date:  2010-01       Impact factor: 2.931

8.  Influence of head positioning during cone-beam CT imaging on the accuracy of virtual 3D models.

Authors:  Maureen van Eijnatten; Jan Wolff; Ruben Pauwels; Kalle Karhu; Ari Hietanen; Henry der Sarkissian; Juha H Koivisto
Journal:  Dentomaxillofac Radiol       Date:  2022-07-13       Impact factor: 3.525

Review 9.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.