OBJECTIVES: The aim was to define image quality and radiation exposure in the recently introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT.
METHODS: A cadaveric head phantom was used for repeated tb volume CT studies (80-120 kV, 25-150 mAs), performed in a 320-row scanner (single rotation, 0.5 mm slice thickness, kernel FC 51) in comparison to 16-row helical CT using standard acquisition parameters (SAP) of 120 kV and 75 mAs (kernel FC 53). Qualitative image evaluation was performed by two radiologists using a 5-point visual analogue scale. Image noise (D(SD)) was determined by region of interest (ROI) based measurements in cadaveric as well as water phantom studies. Dosimetric measurements of the effective dose (ED) and organ dose (OD) of the lens were performed.
RESULTS: Image quality of 320-row tb CT was equivalent to 16-row CT for SAP scans, resulting in image noise levels (D(SD) 16-/320-row) of 109/237 and 206/446 for air and bone respectively. D(SD) differences were predominantly (>90%) attributable to the different kernels available for tb studies in 16- and 320-row CT. Radiation exposure for 16-/320-row SAP scans amounted to 0.36/0.30 mSv (ED) and 10.0/8.4 mGy (lens dose).
CONCLUSION: 320-row volume acquisition in tb CT delivers equivalent image quality to 16-row CT while decreasing radiation exposure figures by one sixth. Image noise increase in 320-row CT is negligible with respect to image quality.

Entities:  

Mesh:

Year:  2010        PMID: 20395460      PMCID: PMC3520229          DOI: 10.1259/dmfr/14139527

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  17 in total

1.  High-resolution petrous bone imaging using multi-slice computerized tomography.

Authors:  R Klingebiel; H C Bauknecht; P Rogalla; U Bockmühl; O Kaschke; M Werbs; R Lehmann
Journal:  Acta Otolaryngol       Date:  2001-07       Impact factor: 1.494

2.  The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.

Authors:  A Tzedakis; J Damilakis; K Perisinakis; J Stratakis; N Gourtsoyiannis
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

3.  Imaging of small high-density structures in CT A phantom study.

Authors:  Empar Rollano-Hijarrubia; R Stokking; Frits van der Meer; Wiro J Niessen
Journal:  Acad Radiol       Date:  2006-07       Impact factor: 3.173

4.  Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging.

Authors:  Shinichiro Mori; Masahiro Endo; Chisato Kondo; Shuji Tanada
Journal:  Acad Radiol       Date:  2006-06       Impact factor: 3.173

5.  Properties of the prototype 256-row (cone beam) CT scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Takanori Tsunoo; Kandatsu Susumu; Shuji Tanada
Journal:  Eur Radiol       Date:  2006-03-28       Impact factor: 5.315

6.  Multi-slice helical CT: scan and reconstruction.

Authors:  H Hu
Journal:  Med Phys       Date:  1999-01       Impact factor: 4.071

7.  High-resolution CT of the chest: radiation dose.

Authors:  J R Mayo; S A Jackson; N L Müller
Journal:  AJR Am J Roentgenol       Date:  1993-03       Impact factor: 3.959

8.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

9.  High resolution computed tomography of the temporal bone.

Authors:  K A Shaffer; V M Haughton; C R Wilson
Journal:  Radiology       Date:  1980-02       Impact factor: 11.105

Review 10.  Multislice CT: technical principles and future trends.

Authors:  Mathias Prokop
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

View more
  2 in total

1.  Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging.

Authors:  Mathias Meyer; Holger Haubenreisser; Rainer Raupach; Bernhard Schmidt; Florian Lietzmann; Christianne Leidecker; Thomas Allmendinger; Thomas Flohr; Lothar R Schad; Stefan O Schoenberg; Thomas Henzler
Journal:  Eur Radiol       Date:  2014-09-08       Impact factor: 5.315

Review 2.  Dose reduction in CT imaging for facial bone trauma in adults: A narrative literature review.

Authors:  Tayla Hooper; Grace Eccles; Talia Milliken; Josephine R Mathieu-Burry; Warren Reed
Journal:  J Med Radiat Sci       Date:  2019-02-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.