Literature DB >> 16530633

3T MR imaging of the musculoskeletal system (Part I): considerations, coils, and challenges.

R Richard Ramnath1.   

Abstract

As 3T MR imaging systems become more wide-spread in the clinical realm, a full understanding of the opportunities for image improvement and the limitations in the applications of the signal gain is needed. It is clear that even with current coil technology, much of the gain in signal can be harnessed effectively; however, continued coil development is necessary to realize the full potential of 3T, especially with the wonderful synergy that can be achieved with the use of parallel imaging and multiple-channel phased-array extremity coils. Furthermore, despite the theoretic imaging challenges at higher field strengths (eg, susceptibility, chemical shift, SAR, pulsation, T1 time prolongation, and T2 time shortening), the techniques and methods that were discussed above can eliminate any obstacles to clinical imaging. This creates excellent opportunities to improve image quality, spatial resolution, and diagnostic accuracy in the musculo-skeletal system. From the author's experience, the superb image quality has impressed referring orthopedic surgeons, and the reduction in scan time has resulted in greater patient satisfaction and reduced anxiety.

Entities:  

Mesh:

Year:  2006        PMID: 16530633     DOI: 10.1016/j.mric.2006.01.001

Source DB:  PubMed          Journal:  Magn Reson Imaging Clin N Am        ISSN: 1064-9689            Impact factor:   2.266


  12 in total

1.  Analysis of tunnel widening after double-bundle ACL reconstruction.

Authors:  Yong Seuk Lee; Sheen-Woo Lee; Shin Woo Nam; Won Seok Oh; Jae Ang Sim; Ji Hoon Kwak; Beom Koo Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-15       Impact factor: 4.342

Review 2.  Musculoskeletal imaging at 3 T: imaging and optimization.

Authors:  James S Meyer
Journal:  Pediatr Radiol       Date:  2008-05

3.  MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

Authors:  Felix P Kuhn; Georg Spinner; Filippo Del Grande; Michael Wyss; Marco Piccirelli; Stefan Erni; Pascal Pfister; Michael Ho; Bert-Ram Sah; Lukas Filli; Dominik A Ettlin; Luigi M Gallo; Gustav Andreisek; Andrei Manoliu
Journal:  Dentomaxillofac Radiol       Date:  2016-12-18       Impact factor: 2.419

4.  Ligaments of the Lisfranc joint in MRI: 3D-SPACE (sampling perfection with application optimized contrasts using different flip-angle evolution) sequence compared to three orthogonal proton-density fat-saturated (PD fs) sequences.

Authors:  Erika J Ulbrich; Veronika Zubler; Reto Sutter; Norman Espinosa; Christian W Pfirrmann; Marco Zanetti
Journal:  Skeletal Radiol       Date:  2012-08-23       Impact factor: 2.199

5.  Bilateral hip imaging at 7 Tesla using a multi-channel transmit technology: initial results presenting anatomical detail in healthy volunteers and pathological changes in patients with avascular necrosis of the femoral head.

Authors:  J M Theysohn; O Kraff; S Orzada; N Theysohn; T Classen; S Landgraeber; M E Ladd; T C Lauenstein
Journal:  Skeletal Radiol       Date:  2013-08-18       Impact factor: 2.199

Review 6.  [High-field and ultrahigh-field magnetic resonance imaging: new possibilities for imaging joints].

Authors:  S Trattnig; T C Mamisch; I Noebauer
Journal:  Z Rheumatol       Date:  2006-12       Impact factor: 1.372

7.  Repair of distal biceps brachii tendon assessed with 3-T magnetic resonance imaging and correlation with functional outcome.

Authors:  Guillaume Alemann; Emmanuel Dietsch; David Gallinet; Laurent Obert; Bruno Kastler; Sébastien Aubry
Journal:  Skeletal Radiol       Date:  2014-12-14       Impact factor: 2.199

8.  Comparative study of imaging at 3.0 T versus 1.5 T of the knee.

Authors:  Scott Wong; Lynne Steinbach; Jian Zhao; Christoph Stehling; C Benjamin Ma; Thomas M Link
Journal:  Skeletal Radiol       Date:  2009-04-07       Impact factor: 2.199

9.  High-resolution morphological and biochemical imaging of articular cartilage of the ankle joint at 3.0 T using a new dedicated phased array coil: in vivo reproducibility study.

Authors:  Goetz H Welsch; Tallal C Mamisch; Michael Weber; Wilhelm Horger; Klaus Bohndorf; Siegfried Trattnig
Journal:  Skeletal Radiol       Date:  2008-06       Impact factor: 2.199

10.  Comparison of 1.5- and 3-T MR imaging for evaluating the articular cartilage of the knee.

Authors:  Pieter Van Dyck; Christoph Kenis; Filip M Vanhoenacker; Valérie Lambrecht; Kristien Wouters; Jan L Gielen; Lieven Dossche; Paul M Parizel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-09       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.