Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Dimitris Mitsouras1, Robert V Mulkern, Frank J Rybicki.   

Abstract

Fast spin echo (FSE) trains elicited by nonselective "hard" refocusing radio frequency (RF) pulses have been proposed as a means to enable application of FSE methods for high-resolution 3D magnetic resonance imaging (MRI). Hard-pulse FSE (HPFSE) trains offer short (3-4 ms) echo spacings, but are unfortunately limited to imaging the entire sample within the coil sensitivity thus requiring lengthy imaging times, consequently limiting clinical application. In this work we formulate and analyze two general-purpose combinations of 3D HPFSE with inner volume (IV) MR imaging to circumvent this limitation. The first method employs a 2D selective RF excitation followed by the HPFSE train and focuses on required properties of the spatial excitation profile with respect to limiting RF pulse duration in the 5-6 ms range. The second method employs two orthogonally selective 1D RF excitations (a 90x degrees - 180y degrees pair) to generate an echo from magnetization within the volume defined by their intersection. Subsequent echoes are formed via the HPFSE train, placing the focus of the method on (a) avoiding spurious echoes that may arise from transverse magnetization located outside the slab intersection when it is unavoidably affected by the nonselective refocusing pulses and (b) avoiding signal losses due to the necessarily different spacing (in time) of the RF pulse applications. The performance of each method is experimentally measured using Carr-Purcell-Meiboom-Gill (CPMG) multi-echo imaging, enabling examination of the magnetization evolution throughout the echo train. The methods as implemented achieve 95% to 97% outer volume signal suppression, and higher suppression appears to be well within reach, by further refinement of the selective RF excitations. Example images of the human brain and spine are presented with each technique. We conclude that the SNR efficiency of volume imaging in conjunction with the short echo spacing afforded by hard pulse trains enables high-resolution 3D HPFSE MRI of a small field-of-view (FOV) with minimal aliasing artifact.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16485424      PMCID: PMC1414094          DOI: 10.1118/1.2148331

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  On the performance and accuracy of 2D navigator pulses.

Authors:  K Nehrke; P Börnert; J Groen; J Smink; J C Böck
Journal:  Magn Reson Imaging       Date:  1999-10       Impact factor: 2.546

2.  Resampling of data between arbitrary grids using convolution interpolation.

Authors:  V Rasche; R Proksa; R Sinkus; P Börnert; H Eggers
Journal:  IEEE Trans Med Imaging       Date:  1999-05       Impact factor: 10.048

3.  3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.

Authors:  R M Botnar; W Y Kim; P Börnert; M Stuber; E Spuentrup; W J Manning
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

4.  Slab scan diffusion imaging.

Authors:  S E Maier
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

5.  Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

Authors:  L P Panych; L Zhao; F A Jolesz; R V Mulkern
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

6.  Optimized single-slab three-dimensional spin-echo MR imaging of the brain.

Authors:  J P Mugler; S Bao; R V Mulkern; C R Guttmann; R L Robertson; F A Jolesz; J R Brookeman
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

7.  Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

Authors:  Lindsey A Crowe; Peter Gatehouse; Guang Zhong Yang; Raad H Mohiaddin; Anitha Varghese; Clare Charrier; Jennifer Keegan; David N Firmin
Journal:  J Magn Reson Imaging       Date:  2003-05       Impact factor: 4.813

8.  Calibration of gradient propagation delays for accurate two-dimensional radiofrequency pulses.

Authors:  Nigel P Davies; Peter Jezzard
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

9.  Implementation of wavelet-encoded MR imaging.

Authors:  L P Panych; P D Jakab; F A Jolesz
Journal:  J Magn Reson Imaging       Date:  1993 Jul-Aug       Impact factor: 4.813

10.  Reduction of field of view for dynamic imaging.

Authors:  X Hu; T Parrish
Journal:  Magn Reson Med       Date:  1994-06       Impact factor: 4.668

View more
  19 in total

1.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

3.  Diagnostic performance of the three-dimensional fast spin echo-Cube sequence in comparison with a conventional imaging protocol in evaluation of the lachrymal drainage system.

Authors:  Jing Zhang; Lang Chen; Qiu-Xia Wang; Rong Liu; Wen-Zhen Zhu; Xin Luo; Li Peng; Wei Xiong
Journal:  Eur Radiol       Date:  2014-10-15       Impact factor: 5.315

4.  Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique.

Authors:  Jing Zhang; Lang Chen; Qiu-Xia Wang; Rong Liu; Wen-Zhen Zhu; Xin Luo; Li Peng; Wei Xiong
Journal:  Neuroradiology       Date:  2015-01-13       Impact factor: 2.804

5.  Three-dimensional printing of MRI-visible phantoms and MR image-guided therapy simulation.

Authors:  Dimitris Mitsouras; Thomas C Lee; Peter Liacouras; Ciprian N Ionita; Todd Pietilla; Stephan E Maier; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2016-02-11       Impact factor: 4.668

6.  Immobilized contrast-enhanced MRI: Gadolinium-based long-term MR contrast enhancement of the vein graft vessel wall.

Authors:  Dimitris Mitsouras; Praveen Kumar Vemula; Peng Yu; Ming Tao; Binh T Nguyen; Christina M Campagna; Jeffrey M Karp; Robert V Mulkern; C Keith Ozaki; Frank J Rybicki
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

7.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

8.  Early animal model evaluation of an implantable contrast agent to enhance magnetic resonance imaging of arterial bypass vein grafts.

Authors:  Dimitrios Mitsouras; Ming Tao; Margreet R de Vries; Kaspar Trocha; Oscar R Miranda; Praveen Kumar Vemula; Kui Ding; Amir Imanzadeh; Frederick J Schoen; Jeffrey M Karp; C Keith Ozaki; Frank J Rybicki
Journal:  Acta Radiol       Date:  2018-01-29       Impact factor: 1.990

9.  A comparison and evaluation of reduced-FOV methods for multi-slice 7T human imaging.

Authors:  Christopher J Wargo; Jay Moore; John C Gore
Journal:  Magn Reson Imaging       Date:  2013-07-25       Impact factor: 2.546

10.  Ankle: isotropic MR imaging with 3D-FSE-cube--initial experience in healthy volunteers.

Authors:  Kathryn J Stevens; Reed F Busse; Eric Han; Anja C S Brau; Philip J Beatty; Christopher F Beaulieu; Garry E Gold
Journal:  Radiology       Date:  2008-12       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.