Calibration of gradient propagation delays for accurate two-dimensional radiofrequency pulses.

Nigel P Davies1, Peter Jezzard.   

Abstract

Hardware-related delays between the requested and actual start times of the gradient waveforms on each physical axis are of particular importance for multidimensional selective excitation in which the synchronization of gradient and radiofrequency (RF) waveforms is critical. A method is proposed for the accurate calibration of gradient propagation delays to optimize the spatial accuracy of 2D RF pulses, although the results may also be used to reduce artifacts in other MR techniques. The sensitivity of 2D RF pulses to uncorrected time shifts between the gradient and RF waveforms was exploited to calibrate accurately the propagation delays on each physical gradient axis. This was achieved using a technique that relates the effect of gradient delays in the component waveforms of a constant-angular rate spiral k-space trajectory 2D RF pulse to the spatial location of the subsequent excitation profile. Comparison was also made with a procedure based on a previously described k-space plotting method, showing broad agreement, but with some discrepancies that illustrate the value of a self-referenced correction method for multidimensional RF pulses. Copyright 2004 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2005        PMID: 15690525     DOI: 10.1002/mrm.20308

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Frank J Rybicki
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

2.  Estimation of k-space trajectories in spiral MRI.

Authors:  Hao Tan; Craig H Meyer
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

3.  Correction of parallel transmission using concurrent RF and gradient field monitoring.

Authors:  Mustafa Çavuşoğlu; Benjamin Emanuel Dietrich; David Otto Brunner; Markus Weiger; Klaas Paul Pruessmann
Journal:  MAGMA       Date:  2017-04-25       Impact factor: 2.310

4.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

5.  Estimating and eliminating the excitation errors in bipolar gradient composite excitations caused by radiofrequency-gradient delay: Example of bipolar spokes pulses in parallel transmission.

Authors:  Desmond H Y Tse; Christopher J Wiggins; Benedikt A Poser
Journal:  Magn Reson Med       Date:  2016-12-26       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.