Literature DB >> 10499679

On the performance and accuracy of 2D navigator pulses.

K Nehrke1, P Börnert, J Groen, J Smink, J C Böck.   

Abstract

The purpose of this study was to investigate and to optimize the performance of two-dimensional spatially selective excitation pulses used for navigator applications on a clinical scanner. The influence of gradient imperfections, off-resonance effects, and incomplete k-space covering on the pencil beam-shaped spatial excitation profile of the 2D RF pulse was studied. The studies involved experiments performed on phantoms and in vivo. In addition, simulations were carried out by numerical integration of the Bloch equations. The accuracy of positioning of the pencil beam was increased by a factor of three by employing a simple correction scheme for the compensation of gradient distortions. The spatial selectivity of the 2D RF pulse was improved by taking sampling density corrections into account. The 2D RF pulse performance was found to be sufficient to monitor the diaphragm motion even at moderate gradient strength. For applications, where a high spatial resolution is required or a less characteristic contrast is present a strong gradient system is recommended.

Mesh:

Year:  1999        PMID: 10499679     DOI: 10.1016/s0730-725x(99)00043-0

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  18 in total

1.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Frank J Rybicki
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

2.  Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approach.

Authors:  Dan Xu; Kevin F King; Yudong Zhu; Graeme C McKinnon; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

Review 3.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Authors:  Chuan Huang; Yoann Petibon; Jinsong Ouyang; Timothy G Reese; Mark A Ahlman; David A Bluemke; Georges El Fakhri
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

5.  Fast T2*-weighted MRI of the prostate at 3 Tesla.

Authors:  Rulon L Hardman; Fadi El-Merhi; Adam J Jung; Steve Ware; Ian M Thompson; Harry T Friel; Qi Peng
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

6.  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys.

Authors:  Hao Song; Dan Ruan; Wenyang Liu; V Andrew Stenger; Rolf Pohmann; Maria A Fernández-Seara; Tejas Nair; Sungkyu Jung; Jingqin Luo; Yuichi Motai; Jingfei Ma; John D Hazle; H Michael Gach
Journal:  Med Phys       Date:  2017-02-21       Impact factor: 4.071

7.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

8.  An MRI-compatible platform for one-dimensional motion management studies in MRI.

Authors:  Joris Nofiele; Qing Yuan; Mohammad Kazem; Ken Tatebe; Quinn Torres; Amit Sawant; Ivan Pedrosa; Rajiv Chopra
Journal:  Magn Reson Med       Date:  2015-10-23       Impact factor: 4.668

9.  Design of multidimensional Shinnar-Le Roux radiofrequency pulses.

Authors:  Chao Ma; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2014-02-27       Impact factor: 4.668

10.  Free-breathing, zero-TE MR lung imaging.

Authors:  Fabio Gibiino; Laura Sacolick; Anne Menini; Luigi Landini; Florian Wiesinger
Journal:  MAGMA       Date:  2014-09-09       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.