Literature DB >> 16470814

Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components.

Luigi Costa1, Pierangiola Bracco, Elena Maria Brach del Prever, Steven M Kurtz, Paolo Gallinaro.   

Abstract

The packaging and chemical stability of both conventional and highly crosslinked polyethylene (PE) components available for clinical use in Italy were analyzed. A total of 100 sterilized PE components were entered by 18 orthopedic manufacturers into the study. Six of the manufacturers were Italian and the remaining were based in Europe or America. Hydroperoxide, oxidation, and trans-vinylene levels within the PE components were characterized using Fourier-transform infrared spectroscopy (FTIR). None of the 31 gas-sterilized components had detectable free radicals, hydroperoxide content, or oxidation. Among radiation-sterilized inserts, the highest oxidation and hydroperoxide levels were associated with gas-permeable and polymer-barrier packaging. To the authors' knowledge, this is the first study that relates elevated oxidation and hydroperoxide content in gamma-sterilized PE components to certain types of contemporary, polymeric barrier packaging.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16470814     DOI: 10.1002/jbm.b.30454

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  14 in total

1.  Do crosslinking and vitamin E stabilization influence microbial adhesions on UHMWPE-based biomaterials?

Authors:  Giuliana Banche; Pierangiola Bracco; Valeria Allizond; Alessandro Bistolfi; Michele Boffano; Andrea Cimino; Elena Maria Brach del Prever; Anna Maria Cuffini
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

2.  Gamma inert sterilization: a solution to polyethylene oxidation?

Authors:  Francisco J Medel; Steven M Kurtz; William J Hozack; Javad Parvizi; James J Purtill; Peter F Sharkey; Daniel MacDonald; Matthew J Kraay; Victor Goldberg; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

3.  Does cyclic stress play a role in highly crosslinked polyethylene oxidation?

Authors:  Francisco Medel; Steven Kurtz; Daniel MacDonald; Francisco Javier Pascual; José Antonio Puértolas
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

4.  Correlation between in vivo stresses and oxidation of UHMWPE in total hip arthroplasty.

Authors:  M Regis; P Bracco; L Giorgini; S Fusi; P Dalla Pria; L Costa; C Schmid
Journal:  J Mater Sci Mater Med       Date:  2014-06-29       Impact factor: 3.896

5.  Clinical, radiological, histological and retrieval findings of Activ-L and Mobidisc total disc replacements: a study of two patients.

Authors:  Shennah Austen; Ilona M Punt; Jack P M Cleutjens; Paul C Willems; Steven M Kurtz; Daniel W MacDonald; Lodewijk W van Rhijn; André van Ooij
Journal:  Eur Spine J       Date:  2012-01-15       Impact factor: 3.134

6.  Gamma-irradiation sterilization in an inert environment: a partial solution.

Authors:  Daniel J Berry; Barbara H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

7.  In vivo oxidation and surface damage in retrieved ethylene oxide-sterilized total knee arthroplasties.

Authors:  Daniel MacDonald; Josa Hanzlik; Peter Sharkey; Javad Parvizi; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

8.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

9.  Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

Authors:  Ilona M Punt; Shennah Austen; Jack P M Cleutjens; Steven M Kurtz; René H M ten Broeke; Lodewijk W van Rhijn; Paul C Willems; André van Ooij
Journal:  Spine (Phila Pa 1976)       Date:  2012-01-15       Impact factor: 3.468

10.  The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements.

Authors:  Steven M Kurtz; Jeffrey M Toth; Ryan Siskey; Lauren Ciccarelli; Dan Macdonald; Jorge Isaza; Todd Lanman; Ilona Punt; Marla Steinbeck; Jan Goffin; André van Ooij
Journal:  Semin Spine Surg       Date:  2012-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.