Literature DB >> 16437233

[Conventional perimetry. Part 3: Static perimetry: grid--strategy--visualisation].

U Schiefer1, J Pätzold, B Wabbels, F Dannheim.   

Abstract

Methods for visual field examination using static strategies began with manual static profile perimetry. The transition from a linear stimulus alignment along the profile section to a two-dimensional grid arrangement introduced the era of static grid perimetry. The use of computers makes it possible to automate and standardise this process, allowing the examiner to choose the visual field area, an adequate grid and the optimal strategy, while leaving the processing, visualisation and recording completely observer-independent. This contribution is based only on conventional static procedures for visual field examination (the use of white on white perimetry) as this technique is easily accessible, standardised and well established in everyday practice.

Mesh:

Year:  2006        PMID: 16437233     DOI: 10.1007/s00347-005-1301-8

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  6 in total

1.  Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies.

Authors:  Paul H Artes; Aiko Iwase; Yuko Ohno; Yoshiaki Kitazawa; Balwantray C Chauhan
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-08       Impact factor: 4.799

Review 2.  [Conventional perimetry I: introduction--basics].

Authors:  U Schiefer; J Pätzold; F Dannheim
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

Review 3.  [Conventional techniques of visual field examination Part 2: confrontation visual field testing -- kinetic perimetry].

Authors:  U Schiefer; J Pätzold; F Dannheim
Journal:  Ophthalmologe       Date:  2005-08       Impact factor: 1.059

4.  SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma.

Authors:  B Bengtsson; A Heijl
Journal:  Acta Ophthalmol Scand       Date:  1998-08

5.  A new generation of algorithms for computerized threshold perimetry, SITA.

Authors:  B Bengtsson; J Olsson; A Heijl; H Rootzén
Journal:  Acta Ophthalmol Scand       Date:  1997-08

6.  An improved method to estimate frequency of false positive answers in computerized perimetry.

Authors:  J Olsson; B Bengtsson; A Heijl; H Rootzén
Journal:  Acta Ophthalmol Scand       Date:  1997-04
  6 in total
  7 in total

1.  [Functional diagnostic options for advanced and end stage glaucoma].

Authors:  A F Scheuerle; U Schiefer; K Rohrschneider
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

Review 2.  [Conventional techniques of visual field examination: part 4 Static perimetry: interpretation--perimetric indices--follow-up--perimetry in childhood].

Authors:  U Schiefer; J Pätzold; B Wabbels; F Dannheim
Journal:  Ophthalmologe       Date:  2006-03       Impact factor: 1.059

Review 3.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059

Review 4.  [Recommendations for a standardized perimetry within the framework of epilepsy surgery].

Authors:  M T Lutz; T Mayer; U Schiefer
Journal:  Ophthalmologe       Date:  2011-07       Impact factor: 1.059

5.  [Conventional perimetry. Antiquated or indispensable for functional glaucoma diagnostics?].

Authors:  F Tonagel; B Voykov; U Schiefer
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

6.  [Peripheral suprathreshold stimulation in preperimetric glaucoma].

Authors:  N Bellios; F K Horn; R Lämmer; K Gottschalk; K Dehne; S Rühl; A G M Jünemann
Journal:  Ophthalmologe       Date:  2008-07       Impact factor: 1.059

7.  Comparison of the new perimetric GATE strategy with conventional full-threshold and SITA standard strategies.

Authors:  Ulrich Schiefer; John P Pascual; Beth Edmunds; Elisabeth Feudner; Esther M Hoffmann; Chris A Johnson; Wolf A Lagrèze; Norbert Pfeiffer; Pamela A Sample; Flemming Staubach; Richard G Weleber; Reinhard Vonthein; Elke Krapp; Jens Paetzold
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-12-05       Impact factor: 4.799

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.