Literature DB >> 16428547

An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients.

Gregory M Janelle1, Nikolaus Gravenstein.   

Abstract

Continuous beat-to-beat arterial blood pressure (BP) monitoring with a simultaneous arterial waveform display is typically achieved with an invasive arterial catheter. We evaluated a noninvasive device, the T-Line Tensymeter, that provides a calibrated arterial pressure waveform from which continuous BP measurements and heart rate may be computed by either a bedside host monitor or the tensymeter device itself. In 25 patients given general anesthesia, we measured systolic, mean, and diastolic BPs via the tensymeter and compared these measurements with those obtained from the contralateral radial artery catheter. Data were analyzed using the Bland Altman test to determine agreement between the two systems. The mean +/- sd bias and precision (mm Hg) were as follows: 1.7 +/- 7.0 and 5.7 +/- 4.4 for systolic BP; 2.3 +/- 6.9 and 5.7 +/- 4.5 for diastolic BP; and 1.7 +/- 5.3 and 4.0 +/- 4.8 for mean BP. Noninvasive pressures from the tensymeter-produced arterial waveform agreed with simultaneous contralateral BPs measured from arterial catheters within an acceptable clinical range for a limited population of surgical patients studied over a systolic arterial BP range from 41 to 189 mm Hg without significant temporal performance degradation. The tensymeter may enable physicians to circumvent arterial cannulation in certain circumstances (such as with low- or intermediate-risk procedures) on patients when beat-to-beat BP measurement is desirable.

Entities:  

Mesh:

Year:  2006        PMID: 16428547     DOI: 10.1213/01.ane.0000194873.52453.bd

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

1.  Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry.

Authors:  Ron Dueck; Oliver Goedje; Paul Clopton
Journal:  J Clin Monit Comput       Date:  2012-01-18       Impact factor: 2.502

2.  The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients.

Authors:  Bernd Saugel; Florian Fassio; Alexander Hapfelmeier; Agnes S Meidert; Roland M Schmid; Wolfgang Huber
Journal:  Intensive Care Med       Date:  2012-06-29       Impact factor: 17.440

3.  Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology.

Authors:  Juan C Ruiz-Rodríguez; Adolf Ruiz-Sanmartín; Vicent Ribas; Jesús Caballero; Alejandra García-Roche; Jordi Riera; Xavier Nuvials; Miriam de Nadal; Oriol de Sola-Morales; Joaquim Serra; Jordi Rello
Journal:  Intensive Care Med       Date:  2013-06-06       Impact factor: 17.440

Review 4.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

5.  Comparison of blood pressure monitoring by applanation tonometry and invasively assessed blood pressure in cardiological patients.

Authors:  G Greiwe; S Hoffmann; L Herich; M S Winkler; C J Trepte; C R Behem; M Petzoldt; D A Reuter; S A Haas
Journal:  J Clin Monit Comput       Date:  2017-12-04       Impact factor: 2.502

6.  Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.

Authors:  Jing Sun; Hanjian Chen; Jun Zheng; Bin Mao; Shengmei Zhu; Jingyi Feng
Journal:  J Clin Monit Comput       Date:  2016-12-20       Impact factor: 2.502

7.  A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.

Authors:  Sándor Földi; Tamás Horváth; Flóra Zieger; Péter Sótonyi; György Cserey
Journal:  J Clin Monit Comput       Date:  2017-10-04       Impact factor: 2.502

8.  Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement.

Authors:  Jarkko Harju; Antti Vehkaoja; Pekka Kumpulainen; Stefano Campadello; Ville Lindroos; Arvi Yli-Hankala; Niku Oksala
Journal:  J Clin Monit Comput       Date:  2017-01-19       Impact factor: 2.502

9.  Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.

Authors:  Nicolas Langwieser; Luisa Prechtl; Agnes S Meidert; Alexander Hapfelmeier; Christian Bradaric; Tareq Ibrahim; Karl-Ludwig Laugwitz; Roland M Schmid; Julia Y Wagner; Bernd Saugel
Journal:  Clin Res Cardiol       Date:  2015-01-25       Impact factor: 5.460

10.  An autocalibrating algorithm for non-invasive cardiac output determination based on the analysis of an arterial pressure waveform recorded with radial artery applanation tonometry: a proof of concept pilot analysis.

Authors:  Bernd Saugel; Agnes S Meidert; Nicolas Langwieser; Julia Y Wagner; Florian Fassio; Alexander Hapfelmeier; Luisa M Prechtl; Wolfgang Huber; Roland M Schmid; Oliver Gödje
Journal:  J Clin Monit Comput       Date:  2013-12-10       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.