Dual-energy digital mammography for calcification imaging: scatter and nonuniformity corrections.

S Cheenu Kappadath1, Chris C Shaw.   

Abstract

Mammographic images of small calcifications, which are often the earliest signs of breast cancer, can be obscured by overlapping fibroglandular tissue. We have developed and implemented a dual-energy digital mammography (DEDM) technique for calcification imaging under full-field imaging conditions using a commercially available aSi:H/CsI:Tl flat-panel based digital mammography system. The low- and high-energy images were combined using a nonlinear mapping function to cancel the tissue structures and generate the dual-energy (DE) calcification images. The total entrance-skin exposure and mean-glandular dose from the low- and high-energy images were constrained so that they were similar to screening-examination levels. To evaluate the DE calcification image, we designed a phantom using calcium carbonate crystals to simulate calcifications of various sizes (212-425 microm) overlaid with breast-tissue-equivalent material 5 cm thick with a continuously varying glandular-tissue ratio from 0% to 100%. We report on the effects of scatter radiation and nonuniformity in x-ray intensity and detector response on the DE calcification images. The nonuniformity was corrected by normalizing the low- and high-energy images with full-field reference images. Correction of scatter in the low- and high-energy images significantly reduced the background signal in the DE calcification image. Under the current implementation of DEDM, utilizing the mammography system and dose level tested, calcifications in the 300-355 microm size range were clearly visible in DE calcification images. Calcification threshold sizes decreased to the 250-280 microm size range when the visibility criteria were lowered to barely visible. Calcifications smaller than approximately 250 microm were usually not visible in most cases. The visibility of calcifications with our DEDM imaging technique was limited by quantum noise, not system noise.

Entities:  

Mesh:

Year:  2005        PMID: 16372415     DOI: 10.1118/1.2064767

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

2.  An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: system description and alignment accuracy.

Authors:  David M Gauntt; Gary T Barnes
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

3.  Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

Authors:  Q Le Huy; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

4.  Characterization and potential applications of a dual-layer flat-panel detector.

Authors:  Linxi Shi; Minghui Lu; N Robert Bennett; Edward Shapiro; Jin Zhang; Richard Colbeth; Josh Star-Lack; Adam S Wang
Journal:  Med Phys       Date:  2020-05-18       Impact factor: 4.071

5.  Compositional breast imaging using a dual-energy mammography protocol.

Authors:  Aurelie D Laidevant; Serghei Malkov; Chris I Flowers; Karla Kerlikowske; John A Shepherd
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

6.  Dual-energy digital mammography for calcification imaging: noise reduction techniques.

Authors:  S Cheenu Kappadath; Chris C Shaw
Journal:  Phys Med Biol       Date:  2008-09-02       Impact factor: 3.609

7.  Quantification of breast arterial calcification using full field digital mammography.

Authors:  Sabee Molloi; Tong Xu; Justin Ducote; Carlos Iribarren
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

8.  The impact of calibration phantom errors on dual-energy digital mammography.

Authors:  Xuanqin Mou; Xi Chen; Lijun Sun; Hengyong Yu; Zhen Ji; Lei Zhang
Journal:  Phys Med Biol       Date:  2008-10-20       Impact factor: 3.609

9.  Dual Energy Method for Breast Imaging: A Simulation Study.

Authors:  V Koukou; N Martini; C Michail; P Sotiropoulou; C Fountzoula; N Kalyvas; I Kandarakis; G Nikiforidis; G Fountos
Journal:  Comput Math Methods Med       Date:  2015-07-13       Impact factor: 2.238

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.