Literature DB >> 16362360

Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR.

C Luring1, H Bathis, F Oczipka, C Trepte, H Lufen, L Perlick, J Grifka.   

Abstract

Mobile and fixed bearing in total knee replacement are still discussed controversially. In a retrospective, matched-pair study, we investigated 40 patients with computer-assisted (BrainLAB) primary total knee replacement (PFC Sigma, DePuy) performed two years before. Twenty patients each received a mobile bearing and a fixed bearing. We compared Womac Score, Knee Society Score, postoperative ROM, fluoroscopic measurement of knee stability in flexion and extension and isokinetic muscle strength using a Biodex-3 dynamometer. Both groups showed similar results concerning WOMAC Score (total rotating bearing: 23.05; fixed bearing: 22.57), KSS (rotating bearing: 174.89; fixed bearing: 176.1). Isokinetic muscle force demonstrated statistically significant superior results for knee flexion in the rotating bearing group. Medio-lateral stability revealed statistically significant superior results for the rotating bearing compared to fixed bearing in extension (P>0.05). In flexion only lateral stability was superior (P>0.05). Two-year clinical follow-up after computer-assisted total knee replacement resulted in good clinical outcome with high patient satisfaction. Statistically significant better values for the rotating platform group were found for the medio-lateral stability in extension and the peak flexion torque.

Entities:  

Mesh:

Year:  2005        PMID: 16362360     DOI: 10.1007/s00167-005-0020-7

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  33 in total

1.  Histiocyte reaction in rabbit femurs to UHMWPE, metal, and ceramic particles in different sizes.

Authors:  T Kubo; K Sawada; K Hirakawa; C Shimizu; T Takamatsu; Y Hirasawa
Journal:  J Biomed Mater Res       Date:  1999-06-15

2.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

3.  Posterior stabilized prosthesis. Results after follow-up of nine to twelve years.

Authors:  S H Stern; J N Insall
Journal:  J Bone Joint Surg Am       Date:  1992-08       Impact factor: 5.284

4.  In vivo laxity of low contact stress mobile-bearing prostheses.

Authors:  Yoshikazu Matsuda; Yoshinori Ishii
Journal:  Clin Orthop Relat Res       Date:  2004-02       Impact factor: 4.176

5.  Survivorship of cemented total knee arthroplasty.

Authors:  D E Font-Rodriguez; G R Scuderi; J N Insall
Journal:  Clin Orthop Relat Res       Date:  1997-12       Impact factor: 4.176

6.  Mechanisms of failure in total knee arthroplasty.

Authors:  J R Moreland
Journal:  Clin Orthop Relat Res       Date:  1988-01       Impact factor: 4.176

7.  Aggressive granulomatous lesions in cementless total hip arthroplasty.

Authors:  S Santavirta; V Hoikka; A Eskola; Y T Konttinen; T Paavilainen; K Tallroth
Journal:  J Bone Joint Surg Br       Date:  1990-11

8.  Validation study of a computerized version of the Western Ontario and McMaster Universities VA3.0 Osteoarthritis Index.

Authors:  N Bellamy; J Campbell; J Stevens; L Pilch; C Stewart; Z Mahmood
Journal:  J Rheumatol       Date:  1997-12       Impact factor: 4.666

9.  A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial.

Authors:  A J Price; J L Rees; D Beard; E Juszczak; S Carter; S White; R de Steiger; C A F Dodd; M Gibbons; P McLardy-Smith; J W Goodfellow; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2003-01

10.  Response of three murine macrophage populations to particulate debris: bone resorption in organ cultures.

Authors:  T T Glant; J J Jacobs
Journal:  J Orthop Res       Date:  1994-09       Impact factor: 3.494

View more
  12 in total

1.  Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction.

Authors:  C Lüring; F Oczipka; L Perlick; M Tingart; J Grifka; H Bäthis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-22       Impact factor: 4.342

Review 2.  Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis.

Authors:  Toby O Smith; Farshid Ejtehadi; Rachel Nichols; Leigh Davies; Simon T Donell; Caroline B Hing
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-25       Impact factor: 4.342

3.  Functional outcome of PFC Sigma fixed and rotating-platform total knee arthroplasty. A prospective randomised controlled trial.

Authors:  Birgit Hanusch; Thai Nurn Lou; Gary Warriner; Anthony Hui; Paul Gregg
Journal:  Int Orthop       Date:  2009-11-08       Impact factor: 3.075

Review 4.  Rotating-platform TKA no different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis.

Authors:  Joseph T Moskal; Susan G Capps
Journal:  Clin Orthop Relat Res       Date:  2014-03-04       Impact factor: 4.176

5.  [5-year follow-up of 210 Columbus knee prostheses : A prospective multicentre study].

Authors:  Andreas Fuchs; Philip Häussermann; Dirk Hömig; Björn Gunnar Ochs; Christof A Müller; Peter Helwig; Lukas Konstantinidis
Journal:  Orthopade       Date:  2018-10       Impact factor: 1.087

Review 6.  No differences between fixed- and mobile-bearing total knee arthroplasty.

Authors:  B L Fransen; D C van Duijvenbode; M J M Hoozemans; B J Burger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-06-20       Impact factor: 4.342

7.  Ligament releases do not lead to increased postoperative varus-valgus laxity in flexion and extension: a prospective clinical study in 49 TKR patients.

Authors:  P J C Heesterbeek; N L W Keijsers; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-27       Impact factor: 4.342

8.  Total knee arthroplasty with mobile tibial weight-bearing: clinical evaluation after a minimum of five years of postoperative follow-up.

Authors:  Luiz Gabriel Betoni Guglielmetti; Pedro Pereira da Costa; Ricardo de Paula Leite Cury; Victor Marques de Oliveira; Nilson Roberto Severino; Osmar Pedro Arbix de Camargo
Journal:  Rev Bras Ortop       Date:  2015-05-30

9.  Relationship between outcome scores and knee laxity following total knee arthroplasty: a systematic review.

Authors:  Andreas Kappel; Mogens Laursen; Poul T Nielsen; Anders Odgaard
Journal:  Acta Orthop       Date:  2018-12-20       Impact factor: 3.717

10.  Comparison of mobile-bearing and fixed-bearing designs in high flexion total knee arthroplasty: using a navigation system.

Authors:  Tae Wan Kim; Shi Hwan Park; Jeung Tak Suh
Journal:  Knee Surg Relat Res       Date:  2012-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.