Literature DB >> 2246301

Aggressive granulomatous lesions in cementless total hip arthroplasty.

S Santavirta1, V Hoikka, A Eskola, Y T Konttinen, T Paavilainen, K Tallroth.   

Abstract

We describe six patients with aggressive granulomatous lesions around cementless total hip prostheses. Two patients previously had a cemented prosthesis in the same hip. The Lord prosthesis was used in five patients, the PCA in one. Both prostheses were made of chrome-cobalt alloy. Pain on weight-bearing occurred on average 3.2 years after the cementless arthroplasty, and at that time radiography revealed aggressive granulomatosis around the proximal femoral stem and the acetabular component in five of the patients; one had a large solitary granuloma in the proximal femur. Revision was performed on average 4.8 years after the cementless arthroplasty. At that time all granulomas had grown large in size; while waiting for revision operation, two femoral stem components fractured. All the granulomas showed a uniform histopathology, which included histiocytosis; the cause for these lesions was thought to be plastic debris from the acetabular socket.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2246301

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  31 in total

1.  Periprosthetic bone density as outcome of therapeutic response.

Authors:  Giovanni Iolascon; Gioconda Di Pietro; Annarita Capaldo; Carmine Gioia; Salvatore Gatto; Francesca Gimigliano
Journal:  Clin Cases Miner Bone Metab       Date:  2010-01

2.  Total hip replacement.

Authors:  J P Ivory; J Summerfield; S Thorne; I M Lowdon; D M Williamson
Journal:  Qual Health Care       Date:  1994-06

3.  The fate of grafting acetabular defects during revision total hip arthroplasty.

Authors:  Nathan A Mall; Ryan M Nunley; Kirk E Smith; William J Maloney; John C Clohisy; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

4.  Aggressive granulomatosis of the hip: a forgotten mode of aseptic failure.

Authors:  Pablo Ariel Isidoro Slullitel; Rodrigo Brandariz; Jose Ignacio Oñativia; German Farfalli; Fernando Comba; Francisco Piccaluga; Martin Buttaro
Journal:  Int Orthop       Date:  2018-11-30       Impact factor: 3.075

5.  Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR.

Authors:  C Luring; H Bathis; F Oczipka; C Trepte; H Lufen; L Perlick; J Grifka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-12-14       Impact factor: 4.342

6.  Biocompatibility of hydroxyapatite-coated hip prostheses.

Authors:  S Santavirta; D Nordström; P Ylinen; Y T Konttinen; T Silvennoinen; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

7.  Arthroplasty implant biomaterial particle associated macrophages differentiate into lacunar bone resorbing cells.

Authors:  R Pandey; J Quinn; C Joyner; D W Murray; J T Triffitt; N A Athanasou
Journal:  Ann Rheum Dis       Date:  1996-06       Impact factor: 19.103

8.  Effects of titanium particle size on osteoblast functions in vitro and in vivo.

Authors:  Moon G Choi; Hae S Koh; Daniel Kluess; Daniel O'Connor; Anshu Mathur; George A Truskey; Janet Rubin; David X F Zhou; K-L Paul Sung
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-08       Impact factor: 11.205

9.  Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.

Authors:  Thomas M Grupp; James J Yue; Rolando Garcia; Janet Basson; Jens Schwiesau; Bernhard Fritz; Wilhelm Blömer
Journal:  Eur Spine J       Date:  2008-12-03       Impact factor: 3.134

10.  Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery.

Authors:  Luca Pierannunzii; Florian Fischer; Marco d'Imporzano
Journal:  J Orthop Traumatol       Date:  2008-10-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.