Literature DB >> 15021144

In vivo laxity of low contact stress mobile-bearing prostheses.

Yoshikazu Matsuda1, Yoshinori Ishii.   

Abstract

A stress arthrometric study was done on 60 knees in 54 patients with total knee arthroplasties using a Telos arthrometer, to determine anteroposterior and abduction and adduction laxity and to evaluate the relationship between laxity and retention of the posterior cruciate ligament using low contact stress mobile-bearing prostheses. Thirty knees had posterior cruciate ligament-retaining and 30 had posterior cruciate ligament-sacrificing prostheses. The selected patients had successful knee arthroplasty 6 months previously. Anteroposterior displacement was measured at 30 degree and 90 degree flexion; there were no statistically significant differences between the posterior cruciate ligament-retaining (10.5 mm at 30 degree, 9.3 mm at 90 degree) and posterior cuciate ligament-sacrificing (9.8 mm at 30 degree, 9.7 mm at 90 degree) groups. Abduction and adduction were between 0 degree and 20 degree flexion, there were no significant differences between the two groups. Because all the patients in this study had good clinical results, approximately 10 mm anteroposterior displacement and 4 degree laxity in the coronal direction are considered favorable in low contact stress mobile-bearing prostheses of both designs.

Entities:  

Mesh:

Year:  2004        PMID: 15021144     DOI: 10.1097/00003086-200402000-00022

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  14 in total

1.  In vivo stability of total knee arthroplasty using a navigation system.

Authors:  Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon; Bong Hyun Bae; Sang Jin Park; Sang Gwon Cho
Journal:  Int Orthop       Date:  2006-05-23       Impact factor: 3.075

2.  Preoperative laxity in osteoarthritis patients undergoing total knee arthroplasty.

Authors:  Yoshinori Ishii; Hideo Noguchi; Yoshikazu Matsuda; Hiroshi Kiga; Mitsuhiro Takeda; Shin-Ichi Toyabe
Journal:  Int Orthop       Date:  2007-10-16       Impact factor: 3.075

3.  In vivo anteroposterior translation after meniscal-bearing total knee arthroplasty: effects of soft tissue conditions and flexion angle.

Authors:  Yoshinori Ishii; Hideo Noguchi; Mitsuhiro Takeda; Junko Sato; Tetsuya Sakurai; Shin-Ichi Toyabe
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-07-12

4.  Two-year follow-up on joint stability and muscular function comparing rotating versus fixed bearing TKR.

Authors:  C Luring; H Bathis; F Oczipka; C Trepte; H Lufen; L Perlick; J Grifka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-12-14       Impact factor: 4.342

5.  Changes in the three-dimensional load-bearing axis after mobile-bearing total knee arthroplasty.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Nobukazu Ezawa; Shin-Ichi Toyabe
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-04-21

6.  Anteroposterior translation and range of motion after total knee arthroplasty using posterior cruciate ligament-retaining versus posterior cruciate ligament-substituting prostheses.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Tetsuya Sakurai; Shin-Ichi Toyabe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-02       Impact factor: 4.342

7.  Changes in varus-valgus laxity after total knee arthroplasty over time.

Authors:  Mitsuhiro Takeda; Yoshinori Ishii; Hideo Noguchi; Yoshikazu Matsuda; Junko Sato
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-25       Impact factor: 4.342

8.  Total knee arthroplasty using ultra-congruent inserts can provide similar stability and function compared with cruciate-retaining total knee arthroplasty.

Authors:  Eun-Kyoo Song; Hong-An Lim; Sang-Don Joo; Sung-Kyu Kim; Keun-Bae Lee; Jong-Keun Seon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

9.  Comparison of long-term clinical outcomes after bilateral mobile-bearing total knee arthroplasties using PCL-retaining and PCL-substituting implants in the same patients.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Tetsuya Sakurai; Shin-Ichi Toyabe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-30       Impact factor: 4.342

10.  No influence of coronal laxity and alignment on lift-off after well-balanced and aligned total knee arthroplasty.

Authors:  Satoshi Hamai; Hiromasa Miura; Ken Okazaki; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-17       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.