Anterior chamber depth measurement with a-scan ultrasonography, Orbscan II, and IOLMaster.

Hassan Hashemi1, Kamran Yazdani, Shiva Mehravaran, Akbar Fotouhi.   

Abstract

PURPOSE: The authors conducted a comparison of anterior chamber depth (ACD) measurement by 3 devices of EchoScan, Orbscan II, and IOLMaster to assess the validity of the latter 2 and its reliability with Orbscan II.
METHODS: Forty-four myopic patients, 56.8% female, were enrolled in this prospective study. In all 88 eyes, the ACD was first measured with Orbscan II, followed by IOLMaster and EchoScan U3300, both under cycloplegia. The mean (+/-standard deviation) age and spherical equivalent were 30.2+/-8.5 years and -4.98+/-2.67 D, respectively. The difference between ACD measurements by these 3 devices was analyzed using the repeated-measures analysis of variance. Agreement between each pair of devices was assessed by computing the 95% limits of agreement (LoA). Orbscan II reliability was also evaluated by using the 95% LoA between 2 consecutive measurements. P value adjustments for multiple comparisons were performed using the Bonferroni method.
RESULTS: There was a statistically significant difference between measurements made with the 3 devices (p<0.001). The mean difference between Orbscan II and Echoscan ACD measurements was -0.03+/-0.12 mm, with the 95% LoA from -0.25 to +0.20 mm, and between IOLMaster and Echoscan measurements, it was +0.09+/-0.14 mm with the 95% LoA from -0.18 to +0.36 mm. On average, Orbscan II readings were lower and those of IOLMaster were higher than Echoscan readings. Both Orbscan II and IOLMaster agreed with Echoscan in measuring ACD. The 2 readings by Orbscan II had a 95% LoA of -0.05 and +0.07 mm that shows good reliability.
CONCLUSION: ACD measurement differences with the 3 studied devices proved to be statistically significant; however, these minor differences may be clinically negligible depending on the use of the measurement. As an advantage, both Orbscan II and IOLMaster are noncontact, and with their ACD measurements being valid, they may be considered suitable devices for this purpose. In addition, Orbscan II produces highly repeatable ACD measurements.

Entities:  

Mesh:

Year:  2005        PMID: 16276322

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  9 in total

1.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

Review 2.  Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review.

Authors:  Alberto Domínguez-Vicent; Cari Pérez-Vives; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  Int J Ophthalmol       Date:  2016-07-18       Impact factor: 1.779

3.  Effect of tropicamide and homatropine eye drops on a-scan parameters of the phakic normal eyes.

Authors:  Jagdish Bhatia
Journal:  Oman Med J       Date:  2011-01

4.  Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith's technique, and van Herick's method.

Authors:  Frank Eperjesi; Claire Holden
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-09-10       Impact factor: 3.117

5.  Central corneal thickness and anterior chamber depth measurement by Sirius(®) Scheimpflug tomography and ultrasound.

Authors:  J Jorge; Jl Rosado; Ja Díaz-Rey; Jm González-Méijome
Journal:  Clin Ophthalmol       Date:  2013-02-26

6.  Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth.

Authors:  Haya Matuoq Al Farhan
Journal:  BMC Ophthalmol       Date:  2014-02-25       Impact factor: 2.209

7.  The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.

Authors:  Jinho Jeong; Han Song; Jimmy K Lee; Roy S Chuck; Ji-Won Kwon
Journal:  BMC Ophthalmol       Date:  2017-05-02       Impact factor: 2.209

8.  Comparison of Ocular Biometry Using New Swept-source Optical Coherence Tomography-based Optical Biometer with Other Devices.

Authors:  Young Joo Cho; Tae Hyung Lim; Kee Yong Choi; Beom Jin Cho
Journal:  Korean J Ophthalmol       Date:  2018-08

9.  Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

Authors:  Jing Dong; Yaqin Zhang; Haining Zhang; Zhijie Jia; Suhua Zhang; Xiaogang Wang
Journal:  PLoS One       Date:  2018-03-15       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.