Literature DB >> 16217685

Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques.

S Stea1, B Antonietti, F Baruffaldi, M Visentin, B Bordini, A Sudanese, A Toni.   

Abstract

Hylamer polyethylene was introduced in the 1990s as an alternative to conventional polyethylene. Its chemical and physical properties, and especially its high crystallinity, were claimed to improve resistance to wear. Initially Hylamer devices were sterilized by gamma radiation in air, then the technique was changed and gamma radiation was performed in the absence of oxygen. Clinical experience has shown the early loosening of some devices made from Hylamer. The aim of this study was to ascertain whether early wear and consequent osteolysis was linked to the sterilization method. We retrospectively compared 31 patients with hip prostheses with Hylamer liners sterilized by gamma radiation in air (group 1) with 30 patients with the same prosthesis, but sterilized in the absence of oxygen (group 2). The groups were similar for sex, age, disease, head diameter and material. Mean follow-up was 84 months and no clinical signs of failure were present. Radiographic measurement revealed that wear of group 1 was significantly greater than that of group 2 (0.23 mm/year vs 0.09 mm/year, p=0.001). Periacetabular and femoral osteolysis in group 1 was significantly greater than group 2. In conclusion, the method of sterilization might have influenced the outcome of Hylamer polyethylene liners.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16217685      PMCID: PMC2254662          DOI: 10.1007/s00264-005-0022-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  17 in total

1.  Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study.

Authors:  H McKellop; F W Shen; B Lu; P Campbell; R Salovey
Journal:  J Bone Joint Surg Am       Date:  2000-12       Impact factor: 5.284

Review 2.  Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty.

Authors:  S M Kurtz; O K Muratoglu; M Evans; A A Edidin
Journal:  Biomaterials       Date:  1999-09       Impact factor: 12.479

3.  Early osteolysis following total hip arthroplasty with use of a Hylamer liner in combination with a modular ceramic femoral head. A case report.

Authors:  B K Vaughn; T B Dameron; T W Bauer; Y Mochida; T Akisue; R W Eberle
Journal:  J Bone Joint Surg Am       Date:  1999-10       Impact factor: 5.284

4.  Radiographic wear measurements in a cementless metal-backed modular cobalt-chromium acetabular component.

Authors:  R L Barrack; C Lavernia; E S Szuszczewicz; J Sawhney
Journal:  J Arthroplasty       Date:  2001-10       Impact factor: 4.757

5.  Head penetration into Hylamer acetabular liner sterilized by gamma irradiation in air and in a nitrogen atmosphere.

Authors:  K Yamauchi ; Y Hasegawa; S Iwasada; S Sakano; S Kitamura; H Warashina; H Iwata
Journal:  J Arthroplasty       Date:  2001-06       Impact factor: 4.757

6.  Sterilization and polyethylene wear: clinical studies to support laboratory data.

Authors:  Christi J Sychterz; Karl F Orishimo; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2004-05       Impact factor: 5.284

7.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

8.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

9.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

10.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

View more
  1 in total

Review 1.  Vitamin E diffused, highly crosslinked UHMWPE: a review.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Int Orthop       Date:  2010-12-01       Impact factor: 3.075

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.