Radiographic wear measurements in a cementless metal-backed modular cobalt-chromium acetabular component.

R L Barrack1, C Lavernia, E S Szuszczewicz, J Sawhney.   

Abstract

Linear polyethylene wear was measured radiographically and correlated with direct measurements of wear from 21 of 24 liners retrieved at revision. An optical comparator was used to assess linear wear using the shadowgraph technique. Postoperative and prerevision radiographs were reviewed to measure the amount of linear wear radiographically. Seven radiographic methods described in the literature were used: 5 were manual techniques, and 2 techniques used a computer-assisted digitizer. Linear regression analysis showed that there was a statistically significant correlation between the radiographic measurements compared with the direct measurement for 4 of the 5 manual techniques but only 1 of the 2 computerized techniques. Based on these results, radiographic wear measurements of cementless, modular components should be considered qualitative rather than quantitative. There is a significant difference in the measurements obtained among various published techniques. The addition of computer digitization to enhance manual methodology does not improve accuracy.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11607896     DOI: 10.1054/arth.2001.26589

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Quantification of clearance and creep in acetabular wear measurements.

Authors:  Mo Saffarini; Thomas Gregory; Eric Vandenbussche
Journal:  Ann Transl Med       Date:  2016-04

2.  Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques.

Authors:  S Stea; B Antonietti; F Baruffaldi; M Visentin; B Bordini; A Sudanese; A Toni
Journal:  Int Orthop       Date:  2005-10-11       Impact factor: 3.075

3.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.

Authors:  Shijun Wang; ShuDong Zhang; YuChi Zhao
Journal:  J Orthop Surg Res       Date:  2013-07-08       Impact factor: 2.359

5.  Wear pattern observations from TDR retrievals using autoregistration of voxel data.

Authors:  Yakov P Shkolnikov; Anton Bowden; Daniel MacDonald; Steven M Kurtz
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-08       Impact factor: 3.405

6.  Direct comparison of polyethylene wear in cemented and uncemented acetabular cups.

Authors:  Håvard Bjerkholt; Oystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-09-02

7.  Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique.

Authors:  Eric Vandenbussche; Mohammed Saffarini; Ulrich Hansen; Fabienne Taillieu; Céline Mutschler; Bernard Augereau; Thomas M Gregory
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.