Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging.

Bernd U Foerster1, Dardo Tomasi, Elisabeth C Caparelli.   

Abstract

Mechanical vibrations of the gradient coil system during readout in echo-planar imaging (EPI) can increase the temperature of the gradient system and alter the magnetic field distribution during functional magnetic resonance imaging (fMRI). This effect is enhanced by resonant modes of vibrations and results in apparent motion along the phase encoding direction in fMRI studies. The magnetic field drift was quantified during EPI by monitoring the resonance frequency interleaved with the EPI acquisition, and a novel method is proposed to correct the apparent motion. The knowledge on the frequency drift over time was used to correct the phase of the k-space EPI dataset. Since the resonance frequency changes very slowly over time, two measurements of the resonance frequency, immediately before and after the EPI acquisition, are sufficient to remove the field drift effects from fMRI time series. The frequency drift correction method was tested "in vivo" and compared to the standard image realignment method. The proposed method efficiently corrects spurious motion due to magnetic field drifts during fMRI. (c) 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16215962      PMCID: PMC2408718          DOI: 10.1002/mrm.20695

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  The effects of motion on parametric fMRI analysis techniques.

Authors:  N A Thacker; E Burton; A J Lacey; A Jackson
Journal:  Physiol Meas       Date:  1999-08       Impact factor: 2.833

2.  Field-frequency locked in vivo proton MRS on a whole-body spectrometer.

Authors:  P G Henry; P F van de Moortele; E Giacomini; A Nauerth; G Bloch
Journal:  Magn Reson Med       Date:  1999-10       Impact factor: 4.668

3.  Gradient-induced acoustic and magnetic field fluctuations in a 4T whole-body MR imager.

Authors:  Y Wu; B A Chronik; C Bowen; C K Mechefske; B K Rutt
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

4.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

5.  Functional MRI statistical software packages: a comparative analysis.

Authors:  S Gold; B Christian; S Arndt; G Zeien; T Cizadlo; D L Johnson; M Flaum; N C Andreasen
Journal:  Hum Brain Mapp       Date:  1998       Impact factor: 5.038

6.  Centric ordering is superior to gradient moment nulling for motion artifact reduction in EPI.

Authors:  F A Jaffer; H Wen; P Jezzard; R S Balaban; S D Wolff
Journal:  J Magn Reson Imaging       Date:  1997 Nov-Dec       Impact factor: 4.813

7.  Automated image registration: I. General methods and intrasubject, intramodality validation.

Authors:  R P Woods; S T Grafton; C J Holmes; S R Cherry; J C Mazziotta
Journal:  J Comput Assist Tomogr       Date:  1998 Jan-Feb       Impact factor: 1.826

8.  Gradient moment smoothing: a new flow compensation technique for multi-shot echo-planar imaging.

Authors:  G S Slavin; S J Riederer
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

9.  Ghost artifact reduction for echo planar imaging using image phase correction.

Authors:  M H Buonocore; L Gao
Journal:  Magn Reson Med       Date:  1997-07       Impact factor: 4.668

10.  Characterization and prediction of gradient acoustic noise in MR imagers.

Authors:  R A Hedeen; W A Edelstein
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

View more
  54 in total

1.  Functional connectivity density mapping.

Authors:  Dardo Tomasi; Nora D Volkow
Journal:  Proc Natl Acad Sci U S A       Date:  2010-05-10       Impact factor: 11.205

2.  Probing signal phase in direct visualization of short transverse relaxation time component (ViSTa).

Authors:  Daeun Kim; Hyo Min Lee; Se-Hong Oh; Jongho Lee
Journal:  Magn Reson Med       Date:  2014-08-22       Impact factor: 4.668

3.  Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs).

Authors:  Gizeaddis L Simegn; Andre J W Van der Kouwe; Frances C Robertson; Ernesta M Meintjes; Ali Alhamud
Journal:  Magn Reson Med       Date:  2018-12-02       Impact factor: 4.668

4.  Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field.

Authors:  AbdEl Monem El-Sharkawy; Michael Schär; Paul A Bottomley; Ergin Atalar
Journal:  MAGMA       Date:  2006-10-17       Impact factor: 2.310

5.  Ultrafast method for mapping local functional connectivity hubs in the human brain.

Authors:  Dardo Tomasi; Nora D Volkow
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

6.  Signal fluctuations induced by non-T1-related confounds in variable TR fMRI experiments.

Authors:  Shuowen Hu; Olumide Olulade; Gregory G Tamer; Wen-Ming Luh; Thomas M Talavage
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

7.  Assessment of frequency drift on CEST MRI and dynamic correction: application to gagCEST at 7 T.

Authors:  Johannes Windschuh; Moritz Zaiss; Philipp Ehses; Jae-Seung Lee; Alexej Jerschow; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2018-05-31       Impact factor: 4.668

8.  Improving contrast to noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession.

Authors:  Jongho Lee; Masaki Fukunaga; Jeff H Duyn
Journal:  Neuroimage       Date:  2010-10-30       Impact factor: 6.556

9.  Prospective frequency correction using outer volume suppression-localized navigator for MR spectroscopy and spectroscopic imaging.

Authors:  Chu-Yu Lee; In-Young Choi; Phil Lee
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

10.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.