Literature DB >> 10502751

Field-frequency locked in vivo proton MRS on a whole-body spectrometer.

P G Henry1, P F van de Moortele, E Giacomini, A Nauerth, G Bloch.   

Abstract

The stability of the main magnetic field is critical for prolonged in vivo magnetic resonance spectroscopy (MRS) acquisitions, especially for difference spectroscopy. This study was focused on the implementation and optimization of a field-frequency lock (FFL) on a whole body spectrometer, to correct the main field drift during localized proton MRS of the human brain. The FFL was achieved through a negative feed-back applied in real time on the Z0 shim coil current, after calculation of the frequency shift from a reference signal. This signal was obtained from the whole head with a small flip angle acquisition interleaved with the PRESS acquisition of interest. To avoid propagation of the important short-term time-correlated fluctuations of the head water frequency (mainly due to respiratory motion) onto Z0 correction, the sampling rate of the reference frequency and the smoothing window for the Z0 correction were carefully optimized. Thus, an effective FFL was demonstrated in vivo with no significant increase of the short-term variance of the water frequency. Magn Reson Med 1999 42:636-642, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10502751     DOI: 10.1002/(sici)1522-2594(199910)42:4<636::aid-mrm4>3.0.co;2-i

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging.

Authors:  Bernd U Foerster; Dardo Tomasi; Elisabeth C Caparelli
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

2.  Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field.

Authors:  AbdEl Monem El-Sharkawy; Michael Schär; Paul A Bottomley; Ergin Atalar
Journal:  MAGMA       Date:  2006-10-17       Impact factor: 2.310

3.  Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

Authors:  Assaf Tal; Oded Gonen
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

4.  Improved chemical exchange saturation transfer imaging with real-time frequency drift correction.

Authors:  Ruibin Liu; Hongxi Zhang; Weiming Niu; Can Lai; Qiuping Ding; Weibo Chen; Sayuan Liang; Jinyuan Zhou; Dan Wu; Yi Zhang
Journal:  Magn Reson Med       Date:  2019-01-30       Impact factor: 4.668

5.  Prospective frequency correction for macromolecule-suppressed GABA editing at 3T.

Authors:  Richard A E Edden; Georg Oeltzschner; Ashley D Harris; Nicolaas A J Puts; Kimberly L Chan; Vincent O Boer; Michael Schär; Peter B Barker
Journal:  J Magn Reson Imaging       Date:  2016-05-30       Impact factor: 4.813

6.  Real-time motion and B0 correction for localized adiabatic selective refocusing (LASER) MRSI using echo planar imaging volumetric navigators.

Authors:  Aaron T Hess; Ovidiu C Andronesi; M Dylan Tisdall; A Gregory Sorensen; André J W van der Kouwe; Ernesta M Meintjes
Journal:  NMR Biomed       Date:  2011-07-28       Impact factor: 4.044

7.  Real-time motion and B0 corrected single voxel spectroscopy using volumetric navigators.

Authors:  Aaron T Hess; M Dylan Tisdall; Ovidiu C Andronesi; Ernesta M Meintjes; André J W van der Kouwe
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

8.  Prospective frequency correction using outer volume suppression-localized navigator for MR spectroscopy and spectroscopic imaging.

Authors:  Chu-Yu Lee; In-Young Choi; Phil Lee
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

9.  Preprocessing, analysis and quantification in single-voxel magnetic resonance spectroscopy: experts' consensus recommendations.

Authors:  Jamie Near; Ashley D Harris; Christoph Juchem; Roland Kreis; Małgorzata Marjańska; Gülin Öz; Johannes Slotboom; Martin Wilson; Charles Gasparovic
Journal:  NMR Biomed       Date:  2020-02-21       Impact factor: 4.044

10.  MEGA-PRESS of GABA+: Influences of acquisition parameters.

Authors:  Dinesh K Deelchand; Małgorzata Marjańska; Pierre-Gilles Henry; Melissa Terpstra
Journal:  NMR Biomed       Date:  2019-10-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.