Literature DB >> 16214009

The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures.

Keith R Berend1, Adolph V Lombardi, Thomas H Mallory, Joanne B Adams, Jackie H Russell, Kari L Groseth.   

Abstract

Constrained acetabular components can treat or prevent instability after total hip arthroplasty (THA). We examine long-term results of 755 consecutive constrained THA in 720 patients (1986-1993; 62 primary, 59 conversion, 565 revision, 60 reimplantation, and 9 total femur). Eighty-three patients (88 THAs) were lost before 10-year follow-up, leaving 639 patients (667 THAs) available for study. Dislocation occurred in 117 hips (17.5%), in 37 (28.9%) of 128 constrained for recurrent dislocation, and 46 (28.2%) of 163 with dislocation history. Other reoperations were for aseptic loosening (51, 7.6% acetabular; 28, 4.2% stem; 16, 2.4% combined), infection (40, 6.0%), periprosthetic fracture (19, 2.8%), stem breakage (2, 0.3%), cup malposition (1, 0.1%), dissociated insert (1, 0.1%), dissociated femoral head (1, 0.1%), and impingement of 1 broken (0.1%) and 4 (0.6%) dissociated constraining rings. Although constrained acetabular components prevented recurrent dislocation in 71.1%, they should be used cautiously, with a 42.1% long-term failure rate observed in this series. Dislocation was common despite constraint with previous history as a significant risk.

Entities:  

Mesh:

Year:  2005        PMID: 16214009     DOI: 10.1016/j.arth.2005.06.001

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  38 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  The use of a cemented dual mobility socket to treat recurrent dislocation.

Authors:  Moussa Hamadouche; David J Biau; Denis Huten; Thierry Musset; François Gaucher
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  Use of a dual mobility socket to manage total hip arthroplasty instability.

Authors:  Olivier Guyen; Vincent Pibarot; Gualter Vaz; Christophe Chevillotte; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2008-09-09       Impact factor: 4.176

4.  Are abductor muscle quality and previous revision surgery predictors of constrained liner failure in hip arthroplasty?

Authors:  Michael G Zywiel; Loi'y H Mustafa; Peter M Bonutti; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-20       Impact factor: 3.075

Review 5.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

6.  CORR Insights®: What Is the Survivorship of Revision Surgery Performed for the Chronically Dislocated THA?

Authors:  Denis Nam
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

7.  Instability after total hip arthroplasty.

Authors:  Brian C Werner; Thomas E Brown
Journal:  World J Orthop       Date:  2012-08-18

8.  Adventure sports and sexual freedom hip replacement: the tripolar hip.

Authors:  James W Pritchett
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-06-28

9.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

10.  The unstable total hip replacement.

Authors:  F D'Angelo; L Murena; G Zatti; P Cherubino
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.