Literature DB >> 16195075

Guidelines for standardization of radiostereometry (RSA) of implants.

Edward R Valstar1, Richie Gill, Leif Ryd, Gunnar Flivik, Niclas Börlin, Johan Kärrholm.   

Abstract

There is a need for standardization of radiostereometric (RSA) investigations to facilitate comparison of outcome reported from different research groups. In this document, 6 research centers have agreed upon standards for terminology, description and use of RSA arrangement including radiographic set-up and techniques. Consensus regarding minimum requirements for marker stability and scatter, choice of coordinate systems, and preferred way of describing prosthetic micromotion is of special interest. Some notes on data interpretation are also presented. Validation of RSA should be standardized by preparation of protocols for assessment of accuracy and precision. Practical issues related to loading of the joint by weight bearing or other conditions, follow-up intervals, length of follow-up, radiation dose, and the exclusion of patients due to technical errors are considered. Finally, we present a checklist of standardized output that should be included in any clinical RSA paper.This document will form the basis of a detailed standardization protocol under supervision of ISO and the European Standards Working Group on Joint Replacement Implants (CEN/TC 285/WG4). This protocol will facilitate inclusion of RSA in a standard protocol for implant testing before it is released for general use. Such a protocol-also including other recognized clinical outcome parameters-will reduce the risk of implanting potentially inferior prostheses on a large scale.

Entities:  

Mesh:

Year:  2005        PMID: 16195075     DOI: 10.1080/17453670510041574

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  169 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Differences in fixation stability between spacer plate and plate fixator following high tibial osteotomy.

Authors:  D Pape; D Kohn; N van Giffen; A Hoffmann; R Seil; O Lorbach
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-09       Impact factor: 4.342

3.  Precision and accuracy measurement of radiostereometric analysis applied to movement of the sacroiliac joint.

Authors:  Thomas J Kibsgård; Olav Røise; Britt Stuge; Stephan M Röhrl
Journal:  Clin Orthop Relat Res       Date:  2012-06-14       Impact factor: 4.176

4.  Early migration of the cemented tibial component of unicompartmental knee arthroplasty: a radiostereometry study.

Authors:  Andrea Ensini; Paolo Barbadoro; Alberto Leardini; Fabio Catani; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-04       Impact factor: 4.342

5.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

6.  Fixation and bone remodeling around a low stiffness stem in revision surgery.

Authors:  Johan Kärrholm; Reza Razaznejad
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

7.  Percutaneous epiphysiodesis in the proximal tibia by a single-portal approach: evaluation by radiostereometric analysis.

Authors:  Joachim Horn; Ragnhild Beate Gunderson; Anders Wensaas; Harald Steen
Journal:  J Child Orthop       Date:  2013-06-12       Impact factor: 1.548

8.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

9.  The influence of a suction device on fixation of a cemented cup using RSA.

Authors:  A John Timperley; Sarah L Whitehouse; Patrick G Hourigan
Journal:  Clin Orthop Relat Res       Date:  2008-11-08       Impact factor: 4.176

10.  Randomised clinical trial assessing migration of uncemented primary total hip replacement stems, with and without autologous impaction bone grafting.

Authors:  Michael Rutherford; Riaz J K Khan; Daniel P Fick; Samantha Haebich; Oscar Nivbrant; Thomas Kozak
Journal:  Int Orthop       Date:  2019-01-31       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.