D Pape1, D Kohn, N van Giffen, A Hoffmann, R Seil, O Lorbach. 1. Centre Hospitalier de Luxembourg, Akademisches Lehrkrankenhaus der Universitätskliniken des Saarlandes, 78, rue d'Eich, 1460, Luxembourg, Luxembourg. dietrichpape@yahoo.de
Abstract
PURPOSE: Since in vivo stability following high tibial osteotomy is unknown, surgeons customize the postoperative rehabilitation to the assumed implant stability, leaving us with numerous rehabilitation protocols. The purpose of the study is to quantify the fixation stability of different open-wedge high tibial osteotomy implants. It is hypothesized that the higher fixation stability of a plate fixator justifies early weight bearing. METHODS: In this prospective 30-subject clinical trial, fixation stability was determined over a 2-year period using radiostereometric analysis (RSA). Patients were assigned to two angle-stable osteotomy plates: a spacer plate with 6 postoperative weeks of feather-touch weight bearing versus a plate fixator with 2 postoperative weeks of feather-touch weight bearing. RESULTS: Postoperative RSA data showed a significant higher lateral translation of the distal tibia and a significantly increased subsidence, varus and internal rotation of the tibial head in the spacer plate compared to the plate fixator group. Weight bearing following spacer plate fixation induced significant micromotion 6 weeks after surgery. Three months after surgery, bone healing was achieved regardless of the used implant. CONCLUSIONS: Early weight bearing is appropriate for plate fixator fixation. The 6-week period of delayed weight bearing following spacer plate fixation is inadequate and should be prolonged presumably up to 8-10 weeks to avoid pseudarthrosis and/or recurrence of varus angulation. LEVEL OF EVIDENCE: Level II, diagnostic study--investigating a diagnostic test.
PURPOSE: Since in vivo stability following high tibial osteotomy is unknown, surgeons customize the postoperative rehabilitation to the assumed implant stability, leaving us with numerous rehabilitation protocols. The purpose of the study is to quantify the fixation stability of different open-wedge high tibial osteotomy implants. It is hypothesized that the higher fixation stability of a plate fixator justifies early weight bearing. METHODS: In this prospective 30-subject clinical trial, fixation stability was determined over a 2-year period using radiostereometric analysis (RSA). Patients were assigned to two angle-stable osteotomy plates: a spacer plate with 6 postoperative weeks of feather-touch weight bearing versus a plate fixator with 2 postoperative weeks of feather-touch weight bearing. RESULTS: Postoperative RSA data showed a significant higher lateral translation of the distal tibia and a significantly increased subsidence, varus and internal rotation of the tibial head in the spacer plate compared to the plate fixator group. Weight bearing following spacer plate fixation induced significant micromotion 6 weeks after surgery. Three months after surgery, bone healing was achieved regardless of the used implant. CONCLUSIONS: Early weight bearing is appropriate for plate fixator fixation. The 6-week period of delayed weight bearing following spacer plate fixation is inadequate and should be prolonged presumably up to 8-10 weeks to avoid pseudarthrosis and/or recurrence of varus angulation. LEVEL OF EVIDENCE: Level II, diagnostic study--investigating a diagnostic test.
Authors: Michel P J van den Bekerom; Thomas W Patt; Miriam Y Kleinhout; Harm M van der Vis; G H Rob Albers Journal: J Knee Surg Date: 2008-01 Impact factor: 2.757
Authors: S Schröter; A Ateschrang; W Löwe; H Nakayama; U Stöckle; C Ihle Journal: Knee Surg Sports Traumatol Arthrosc Date: 2015-04-09 Impact factor: 4.342
Authors: Rene Burchard; Denise Katerla; Marina Hammer; Anke Pahlkötter; Christian Soost; Gerhard Dietrich; Arne Ohrndorf; Wolfgang Richter; Markus Lengsfeld; Hans-Jürgen Christ; Jan Adriaan Graw; Claus-Peter Fritzen Journal: Int Orthop Date: 2018-02-01 Impact factor: 3.075
Authors: Sandro F Fucentese; Philippe M Tscholl; Reto Sutter; Peter U Brucker; Dominik C Meyer; Peter P Koch Journal: Knee Surg Sports Traumatol Arthrosc Date: 2018-11-19 Impact factor: 4.342