Literature DB >> 16177486

First experimental results of time-of-flight reconstruction on an LSO PET scanner.

Maurizio Conti1, Bernard Bendriem, Mike Casey, Mu Chen, Frank Kehren, Christian Michel, Vladimir Panin.   

Abstract

Time-of-flight (TOF) positron emission tomography (PET) was studied and preliminarily developed in the 1980s, but the lack of a scintillator able to deliver at the same time proper time resolution and stopping power has prevented this technique from becoming widespread and commercially available. With the introduction of LSO in PET, TOF is now a feasible option. TOF reconstruction has been implemented in the CPS Hi-Rez PET scanner, both with 2D filtered-back-projection (FBP2D) and 3D ordered subset expectation maximization (OSEM3D). A new procedure has been introduced in the time alignment to compensate for the limited digital time resolution of the present electronics. A preliminary version of scatter correction for TOF has been devised and is presented. The measured time resolution of 1.2 ns (FWHM) allowed for a signal-to-noise ratio increase of about 50% in phantoms of about 40 cm transaxial size, or a gain larger than 2 in noise equivalent counts (NEC). TOF reconstruction has shown the expected improvement in SNR, both in simulation and experimental data. First experimental results show two improvements of TOF reconstruction over conventional (non-TOF) reconstruction: a lower noise level and a better capability to resolve structures deep inside large objects.

Mesh:

Year:  2005        PMID: 16177486     DOI: 10.1088/0031-9155/50/19/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  46 in total

1.  Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08       Impact factor: 9.236

2.  Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study.

Authors:  Suleman Surti; Joshua Scheuermann; Georges El Fakhri; Margaret E Daube-Witherspoon; Ruth Lim; Nathalie Abi-Hatem; Elie Moussallem; Francois Benard; David Mankoff; Joel S Karp
Journal:  J Nucl Med       Date:  2011-04-15       Impact factor: 10.057

3.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

4.  Detection performance analysis for time-of-flight PET.

Authors:  Nannan Cao; Ronald H Huesman; William W Moses; Jinyi Qi
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

5.  Analytical properties of time-of-flight PET data.

Authors:  Sanghee Cho; Sangtae Ahn; Quanzheng Li; Richard M Leahy
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

6.  Design considerations for a limited angle, dedicated breast, TOF PET scanner.

Authors:  S Surti; J S Karp
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

7.  Optimization of time-of-flight reconstruction on Philips GEMINI TF.

Authors:  Stefaan Vandenberghe; Larry van Elmbt; Michel Guerchaft; Enrico Clementel; Jeroen Verhaeghe; Anne Bol; Ignace Lemahieu; Max Lonneux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

Review 8.  Focus on time-of-flight PET: the benefits of improved time resolution.

Authors:  Maurizio Conti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-13       Impact factor: 9.236

Review 9.  Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: A technical perspective.

Authors:  Jonathan B Moody; Benjamin C Lee; James R Corbett; Edward P Ficaro; Venkatesh L Murthy
Journal:  J Nucl Cardiol       Date:  2015-04-14       Impact factor: 5.952

10.  An assessment of the impact of incorporating time-of-flight information into clinical PET/CT imaging.

Authors:  Cristina Lois; Bjoern W Jakoby; Misty J Long; Karl F Hubner; David W Barker; Michael E Casey; Maurizio Conti; Vladimir Y Panin; Dan J Kadrmas; David W Townsend
Journal:  J Nucl Med       Date:  2010-01-15       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.