Literature DB >> 20080882

An assessment of the impact of incorporating time-of-flight information into clinical PET/CT imaging.

Cristina Lois1, Bjoern W Jakoby, Misty J Long, Karl F Hubner, David W Barker, Michael E Casey, Maurizio Conti, Vladimir Y Panin, Dan J Kadrmas, David W Townsend.   

Abstract

The introduction of fast scintillators with good stopping power for 511-keV photons has renewed interest in time-of-flight (TOF) PET. The ability to measure the difference between the arrival times of a pair of photons originating from positron annihilation improves the image signal-to-noise ratio (SNR). The level of improvement depends upon the extent and distribution of the positron activity and the time resolution of the PET scanner. While specific estimates can be made for phantom imaging, the impact of TOF PET is more difficult to quantify in clinical situations. The results presented here quantify the benefit of TOF in a challenging phantom experiment and then assess both qualitatively and quantitatively the impact of incorporating TOF information into the reconstruction of clinical studies. A clear correlation between patient body mass index and gain in SNR was observed in this study involving 100 oncology patient studies, with a gain due to TOF ranging from 1.1 to 1.8, which is consistent with the 590-ps time resolution of the TOF PET scanner. The visual comparison of TOF and non-TOF images performed by two nuclear medicine physicians confirmed the advantages of incorporating TOF into the reconstruction, advantages that include better definition of small lesions and image details, improved uniformity, and noise reduction.

Entities:  

Mesh:

Year:  2010        PMID: 20080882      PMCID: PMC2818518          DOI: 10.2967/jnumed.109.068098

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  7 in total

1.  First experimental results of time-of-flight reconstruction on an LSO PET scanner.

Authors:  Maurizio Conti; Bernard Bendriem; Mike Casey; Mu Chen; Frank Kehren; Christian Michel; Vladimir Panin
Journal:  Phys Med Biol       Date:  2005-09-13       Impact factor: 3.609

2.  Fully 3-D PET reconstruction with system matrix derived from point source measurements.

Authors:  Vladimir Y Panin; Frank Kehren; Christian Michel; Michael Casey
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

3.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

4.  Time-of-flight positron emission tomography: status relative to conventional PET.

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1983-01       Impact factor: 10.057

5.  Feasibility of time-of-flight reconstruction in positron emission tomography.

Authors:  N A Mullani; J Markham; M M Ter-Pogossian
Journal:  J Nucl Med       Date:  1980-11       Impact factor: 10.057

6.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities.

Authors:  Suleman Surti; Austin Kuhn; Matthew E Werner; Amy E Perkins; Jeffrey Kolthammer; Joel S Karp
Journal:  J Nucl Med       Date:  2007-03       Impact factor: 10.057

7.  Impact of time-of-flight on PET tumor detection.

Authors:  Dan J Kadrmas; Michael E Casey; Maurizio Conti; Bjoern W Jakoby; Cristina Lois; David W Townsend
Journal:  J Nucl Med       Date:  2009-07-17       Impact factor: 10.057

  7 in total
  67 in total

1.  Evaluation of Hamamatsu PET imaging modules for dedicated TOF-capable scanners.

Authors:  A Stolin; G Jaliparthi; R R Raylman; J Brefczynski-Lewis; S Majewski; J Qi; K Gong; S Dolinsky
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01-23

2.  Comparative analysis of iterative reconstruction algorithms with resolution recovery and time of flight modeling for 18F-FDG cardiac PET: A multi-center phantom study.

Authors:  Roberta Matheoud; Michela Lecchi; Domenico Lizio; Camilla Scabbio; Claudio Marcassa; Lucia Leva; Angelo Del Sole; Carlo Rodella; Luca Indovina; Christian Bracco; Marco Brambilla; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-01-12       Impact factor: 5.952

3.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

4.  Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study.

Authors:  Suleman Surti; Joshua Scheuermann; Georges El Fakhri; Margaret E Daube-Witherspoon; Ruth Lim; Nathalie Abi-Hatem; Elie Moussallem; Francois Benard; David Mankoff; Joel S Karp
Journal:  J Nucl Med       Date:  2011-04-15       Impact factor: 10.057

5.  Detection performance analysis for time-of-flight PET.

Authors:  Nannan Cao; Ronald H Huesman; William W Moses; Jinyi Qi
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

6.  DOI Determination by Rise Time Discrimination in Single-Ended Readout for TOF PET Imaging.

Authors:  R I Wiener; S Surti; J S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2013-06       Impact factor: 1.679

Review 7.  Focus on time-of-flight PET: the benefits of improved time resolution.

Authors:  Maurizio Conti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-13       Impact factor: 9.236

8.  Does time-of-flight improve image quality in the heart?

Authors:  R Glenn Wells; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

9.  A novel method for quantifying peripheral tissue amyloid load by using the radiolabeled amyloidophilic peptide, p5.

Authors:  Jonathan S Wall; Tina Richey; Sally Macy; Eric Heidel; Craig Wooliver; Stephen J Kennel
Journal:  Amyloid       Date:  2013-01-17       Impact factor: 7.141

10.  The effect of time-of-flight and point spread function modeling on 82Rb myocardial perfusion imaging of obese patients.

Authors:  Paul K R Dasari; Judson P Jones; Michael E Casey; Yuanyuan Liang; Vasken Dilsizian; Mark F Smith
Journal:  J Nucl Cardiol       Date:  2018-06-15       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.