Literature DB >> 16804687

Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?

Giovanni Lucignani1.   

Abstract

Mesh:

Year:  2006        PMID: 16804687     DOI: 10.1007/s00259-006-0185-4

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


× No keyword cloud information.
  6 in total

1.  Simultaneous PET and NMR.

Authors:  Paul K Marsden; Daniel Strul; Stephen F Keevil; Steven C R Williams; Diana Cash
Journal:  Br J Radiol       Date:  2002-11       Impact factor: 3.039

2.  First experimental results of time-of-flight reconstruction on an LSO PET scanner.

Authors:  Maurizio Conti; Bernard Bendriem; Mike Casey; Mu Chen; Frank Kehren; Christian Michel; Vladimir Panin
Journal:  Phys Med Biol       Date:  2005-09-13       Impact factor: 3.609

3.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

4.  Investigation of time-of-flight benefit for fully 3-D PET.

Authors:  Suleman Surti; Joel S Karp; Lucretiu M Popescu; Margaret E Daube-Witherspoon; Matthew Werner
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

5.  Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing.

Authors:  Stefaan Vandenberghe; Margaret E Daube-Witherspoon; Robert M Lewitt; Joel S Karp
Journal:  Phys Med Biol       Date:  2006-03-01       Impact factor: 3.609

6.  A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals.

Authors:  S I Ziegler; B J Pichler; G Boening; M Rafecas; W Pimpl; E Lorenz; N Schmitz; M Schwaiger
Journal:  Eur J Nucl Med       Date:  2001-02
  6 in total
  4 in total

1.  PET/MRI: a different spin from under the rim.

Authors:  Rodney J Hicks; Eddie W F Lau
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 2.  Multimodality imaging: beyond PET/CT and SPECT/CT.

Authors:  Simon R Cherry
Journal:  Semin Nucl Med       Date:  2009-09       Impact factor: 4.446

3.  Hybrid imaging is the future of molecular imaging.

Authors:  Rj Hicks; Ewf Lau; Ds Binns
Journal:  Biomed Imaging Interv J       Date:  2007-07-01

4.  Monte Carlo simulation studies on scintillation detectors and image reconstruction of brain-phantom tumors in TOFPET.

Authors:  Nagendra Nath Mondal
Journal:  J Med Phys       Date:  2009-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.