Value of digital volume tomography in patients with conductive hearing loss.

C V Dalchow1, A L Weber, S Bien, N Yanagihara, J A Werner.   

Abstract

Digital volume tomography (DVT) is an extension of panoramic tomography. With this diagnostic technique, characterized by high resolution, a narrow section width (0.125 mm) and three-dimensional display, small pathological processes can be well visualized. Twenty-five patients with the history of a progressive hearing loss were examined with DVT (Accu-I-tomo, Morita, Japan). The results were compared with pre- and intraoperative findings to evaluate the diagnostic value of DVT in cases of erosion of the ossicular chain. With high resolution and artifact-free demonstration of the middle ear and the ossicular chain, it was possible to define its continuity preoperatively by DVT in all 25 cases. An intact ossicular chain was found by DVT in 13 cases and was later confirmed by surgery. The predicted erosion of the ossicles was verified in 12 patients, and a tympanoplasty type III was performed. Digital volume tomography is an excellent technique to examine the middle ear cleft and inner ear, and expands the application of diagnostic possibilities in the lateral skull base. Therefore, improvement in preoperative diagnosis is achieved along with more accurate planning of the surgical procedure. Digital volume tomography delivers a small radiation dose with a high resolution and a low purchase price for the equipment.

Entities:  

Mesh:

Year:  2005        PMID: 16163510     DOI: 10.1007/s00405-005-0995-1

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  25 in total

1.  3D volume rendering using multislice CT for dental implants.

Authors:  M G P Cavalcanti; A Ruprecht; M W Vannier
Journal:  Dentomaxillofac Radiol       Date:  2002-07       Impact factor: 2.419

2.  Usefulness of virtual endoscopic three-dimensional reconstructions of the middle ear.

Authors:  A Morra; G Tirelli; A Rimondini; V Cioffi; M Russolo; V Giacomarra; R Pozzi-Mucelli
Journal:  Acta Otolaryngol       Date:  2002-06       Impact factor: 1.494

3.  [Diagnosis and therapy of stapes fractures and luxations].

Authors:  K Jakse; R Jakse
Journal:  Laryngorhinootologie       Date:  2002-02       Impact factor: 1.057

4.  The predictive value of high resolution computerized tomography in chronic suppurative ear disease.

Authors:  G M O'Donoghue; G J Bates; P Anslow; M P Rothera
Journal:  Clin Otolaryngol Allied Sci       Date:  1987-04

5.  [3-dimensional imaging of temporal bone structures using spiral CT. Initial results in normal temporal bone anatomy].

Authors:  C Reisser; O Schubert; H Weidauer
Journal:  HNO       Date:  1995-10       Impact factor: 1.284

6.  Clinical significance of partial volume averaging of the temporal bone.

Authors:  D W Chakeres
Journal:  AJNR Am J Neuroradiol       Date:  1984 May-Jun       Impact factor: 3.825

7.  Middle ear imaging using virtual endoscopy and its application in patients with ossicular chain anomaly.

Authors:  T Himi; M Sakata; T Shintani; H Mitsuzawa; M Kamagata; J Satoh; H Sugimoto
Journal:  ORL J Otorhinolaryngol Relat Spec       Date:  2000 Nov-Dec       Impact factor: 1.538

Review 8.  CT and MR imaging of congential abnormalities of the inner ear and internal auditory canal.

Authors:  J W Casselman; E F Offeciers; B De Foer; P Govaerts; R Kuhweide; T Somers
Journal:  Eur J Radiol       Date:  2001-11       Impact factor: 3.528

9.  High-resolution CT of the normal and abnormal fallopian canal.

Authors:  A Valavanis; S Kubik; O Schubiger
Journal:  AJNR Am J Neuroradiol       Date:  1983 May-Jun       Impact factor: 3.825

10.  Postinflammatory ossicular fixation: CT analysis with surgical correlation.

Authors:  J D Swartz; R J Wolfson; F I Marlowe; G L Popky
Journal:  Radiology       Date:  1985-03       Impact factor: 11.105

View more
  14 in total

1.  Controlling the position and the dislocation of the middle ear transducer with high-resolution computed tomography and digital volume tomography: implications for the transducers' design.

Authors:  Georgios Kontorinis; Anja M Giesemann; Thomas Witt; Friedrich Goetz; Burkard Schwab
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-22       Impact factor: 2.503

Review 2.  Use of cone beam computed tomography in otolaryngologic treatments.

Authors:  Hamdi Cakli; Cemal Cingi; Yazgi Ay; Fatih Oghan; Torun Ozer; Ercan Kaya
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-27       Impact factor: 2.503

3.  Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study.

Authors:  Afshin Teymoortash; Stella Hamzei; Tobias Murthum; Behfar Eivazi; Ingo Kureck; Jochen A Werner
Journal:  Surg Radiol Anat       Date:  2010-08-13       Impact factor: 1.246

Review 4.  [Digital volume tomography in ENT medicine].

Authors:  M Bremke; R Leppek; J A Werner
Journal:  HNO       Date:  2010-08       Impact factor: 1.284

5.  Measurement and comparison of labyrinthine structures with the digital volume tomography: ancient Egyptian mummies' versus today's temporal bones.

Authors:  C Schmidt; J Harbort; R Knecht; U Grzyska; A Muenscher; C V Dalchow
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-05-12       Impact factor: 2.503

6.  Bionic ear imaging.

Authors:  R Cerini; N Faccioli; M Barillari; M De Iorio; M Carner; V Colletti; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2008-04-02       Impact factor: 3.469

7.  Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT).

Authors:  C Güldner; S Wiegand; R Weiss; S Bien; A Sesterhenn; A Teymoortash; I Diogo
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-30       Impact factor: 2.503

8.  Visualization of anatomy in normal and pathologic middle ears by cone beam CT.

Authors:  Christian Güldner; Isabell Diogo; Eva Bernd; Stephanie Dräger; Magis Mandapathil; Afshin Teymoortash; Hesham Negm; Thomas Wilhelm
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-10-17       Impact factor: 2.503

9.  Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma.

Authors:  E De Smet; G De Praeter; K L A Verstraete; K Wouters; Luc De Beuckeleer; F M H M Vanhoenacker
Journal:  Skeletal Radiol       Date:  2015-03-12       Impact factor: 2.199

10.  Radiation dose saving through the use of cone-beam CT in hearing-impaired patients.

Authors:  N Faccioli; M Barillari; S Guariglia; E Zivelonghi; A Rizzotti; R Cerini; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2009-09-30       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.