Literature DB >> 6426283

Clinical significance of partial volume averaging of the temporal bone.

D W Chakeres.   

Abstract

The effects of partial volume averaging on computed tomographic images of temporal bone structures were evaluated. The models chosen for study included a cadaver stapes, two metallic prosthetic stapes, and a formalin-fixed temporal bone. The studies measured the changes in apparent dimension and Hounsfield units with incremental filling of voxels with metallic densities, changes in the angle of tomographic section in relation to small bony structures, and the effects of soft-tissue silhouetting. The clinical significance of these changes is demonstrated by examples of this phenomenon seen in actual patient examinations. This study confirms that partial volume averaging is one of the primary limitations in resolution of small structures of the temporal bone.

Entities:  

Mesh:

Year:  1984        PMID: 6426283      PMCID: PMC8334138     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  11 in total

Review 1.  Head and neck imaging.

Authors:  W P Dillon
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

2.  Experimental flat-panel high-spatial-resolution volume CT of the temporal bone.

Authors:  Rajiv Gupta; Soenke H Bartling; Samit K Basu; William R Ross; Hartmut Becker; Armin Pfoh; Thomas Brady; Hugh D Curtin
Journal:  AJNR Am J Neuroradiol       Date:  2004-09       Impact factor: 3.825

3.  Value of digital volume tomography in patients with conductive hearing loss.

Authors:  C V Dalchow; A L Weber; S Bien; N Yanagihara; J A Werner
Journal:  Eur Arch Otorhinolaryngol       Date:  2005-09-15       Impact factor: 2.503

4.  Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses.

Authors:  Alessandro Bozzato; Tobias Struffert; Victoria Hertel; Heinrich Iro; Joachim Hornung
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

5.  Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT.

Authors:  D Maret; N Telmon; O A Peters; B Lepage; J Treil; J M Inglèse; A Peyre; J L Kahn; M Sixou
Journal:  Dentomaxillofac Radiol       Date:  2012-12       Impact factor: 2.419

6.  Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments.

Authors:  R Hermans; G Marchal; L Feenstra; A L Baert
Journal:  Neuroradiology       Date:  1995-02       Impact factor: 2.804

7.  Computed tomography of the ossicles.

Authors:  D W Chakeres; D J Weider
Journal:  Neuroradiology       Date:  1985       Impact factor: 2.804

8.  Alveolar bone thickness and fenestration of incisors in untreated Korean patients with skeletal class III malocclusion: A retrospective 3-dimensional cone-beam computed tomography study.

Authors:  Song Hee Oh; Kyung-Yen Nahm; Seong-Hun Kim; Gerald Nelson
Journal:  Imaging Sci Dent       Date:  2020-03-17

9.  Assessment of Differences in the Dimensions of Mandible Condyle Models in Fan- versus Cone-Beam Computer Tomography Acquisition.

Authors:  Bartosz Bielecki-Kowalski; Marcin Kozakiewicz
Journal:  Materials (Basel)       Date:  2021-03-12       Impact factor: 3.623

10.  Performance of Cone Beam Computed Tomography Systems in Visualizing the Cortical Plate in 3D Image Reconstruction: An In Vitro Study.

Authors:  Abbas Shokri; Mohammad Reza Jamalpour; Amir Eskandarloo; Mostafa Godiny; Payam Amini; Atefeh Khavid
Journal:  Open Dent J       Date:  2018-08-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.