Literature DB >> 16160740

Multi-detector row CT imaging of vertebral microstructure for evaluation of fracture risk.

Masako Ito1, Kyoji Ikeda, Masahiko Nishiguchi, Hiroyuki Shindo, Masataka Uetani, Takayuki Hosoi, Hajime Orimo.   

Abstract

UNLABELLED: We applied MDCT for in vivo evaluation of the microarchitecture of human vertebrae. Microstructure parameters, such as structure model index, Euler's number, and bone volume fraction, revealed higher relative risk for prevalent vertebral fracture than did BMD obtained by DXA. Thus, microstructure analysis by MDCT, together with simultaneously obtained volumetric BMD values, is useful for clinical assessment of fracture risk.
INTRODUCTION: BMD measurement by DXA alone has limitations in predicting fracture, and methods for clinical assessment of bone quality, such as microstructure, are awaited. This study was undertaken to examine the applicability of multidetector row CT (MDCT) for in vivo evaluation of trabecular microstructure.
MATERIALS AND METHODS: Optimal conditions for MDCT scanning were determined at a spatial resolution of 250 x 250 x 500 mum, using muCT data of excised human vertebra specimens as a reference. We analyzed the trabecular microstructure of the vertebrae of 82 postmenopausal women (55-76 years old), including 39 women with and 43 without a recent vertebral fracture.
RESULTS: Microstructure indices obtained by MDCT scanning revealed higher relative risk for prevalent vertebral fracture (OR: 16.0 for structure model index, 13.6 for bone volume fraction, and 13.1 for Euler's number) than did spinal BMD obtained by DXA (OR: 4.8). MDCT could also provide volumetric BMD data, which had higher diagnostic value (OR: 12.7) than did DXA.
CONCLUSION: Vertebral microarchitecture can be visualized by MDCT, and microstructure parameters obtained by MDCT, together with volumetric BMD, provided better diagnostic performance for assessing fracture risk than DXA measurement.

Entities:  

Mesh:

Year:  2005        PMID: 16160740     DOI: 10.1359/JBMR.050610

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  77 in total

1.  Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT.

Authors:  Catherine M Phan; Eric A Macklin; Miriam A Bredella; Monica Dadrich; Paul Flechsig; Albert J Yoo; Joshua A Hirsch; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2010-07-25       Impact factor: 2.199

2.  A robust algorithm for thickness computation at low resolution and its application to in vivo trabecular bone CT imaging.

Authors:  Yinxiao Liu; Dakai Jin; Cheng Li; Kathleen F Janz; Trudy L Burns; James C Torner; Steven M Levy; Punam K Saha
Journal:  IEEE Trans Biomed Eng       Date:  2014-07       Impact factor: 4.538

Review 3.  [New techniques for the diagnosis of osteoporosis].

Authors:  A S Issever; T M Link
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

Review 4.  The vertebral fracture cascade in osteoporosis: a review of aetiopathogenesis.

Authors:  A M Briggs; A M Greig; J D Wark
Journal:  Osteoporos Int       Date:  2007-01-06       Impact factor: 4.507

5.  Does thoracic or lumbar spine bone architecture predict vertebral failure strength more accurately than density?

Authors:  E-M Lochmüller; K Pöschl; L Würstlin; M Matsuura; R Müller; T M Link; F Eckstein
Journal:  Osteoporos Int       Date:  2007-10-03       Impact factor: 4.507

6.  Resolution dependence of the non-metric trabecular structure indices.

Authors:  Miki Sode; Andrew J Burghardt; Robert A Nissenson; Sharmila Majumdar
Journal:  Bone       Date:  2007-12-23       Impact factor: 4.398

7.  Trabecular bone structure analysis in the osteoporotic spine using a clinical in vivo setup for 64-slice MDCT imaging: comparison to microCT imaging and microFE modeling.

Authors:  Ahi S Issever; Thomas M Link; Marie Kentenich; Patrik Rogalla; Karsten Schwieger; Markus B Huber; Andrew J Burghardt; Sharmila Majumdar; Gerd Diederichs
Journal:  J Bone Miner Res       Date:  2009-09       Impact factor: 6.741

8.  Role of trabecular microarchitecture in whole-vertebral body biomechanical behavior.

Authors:  Aaron J Fields; Senthil K Eswaran; Michael G Jekir; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2009-09       Impact factor: 6.741

Review 9.  Advanced CT based in vivo methods for the assessment of bone density, structure, and strength.

Authors:  K Engelke; C Libanati; T Fuerst; P Zysset; H K Genant
Journal:  Curr Osteoporos Rep       Date:  2013-09       Impact factor: 5.096

10.  Implications of resolution and noise for in vivo micro-MRI of trabecular bone.

Authors:  Charles Q Li; Jeremy F Magland; Chamith S Rajapakse; X Edward Guo; X Henry Zhang; Branimir Vasilic; Felix W Wehrli
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.