Three-dimensional mechanical properties of the thoracolumbar junction.

T R Oxland1, R M Lin, M M Panjabi.   

Abstract

The thoracolumbar junction region is a frequent site of spinal trauma. Accurate knowledge of the normal mechanical behavior of the intervertebral joints in this region is of importance to the clinician in treating the spinal injuries. The present study documented the complete three-dimensional motions of levels T11-T12 and T12-L1 in the thoracolumbar region. Pure moments of flexion/extension, bilateral axial torque, and bilateral lateral bending were applied to 11 three-vertebrae human cadaveric specimens (T11-L1) to a maximum of 7.5 Nm. Intervertebral motions were calculated using stereophotogrammetry and presented in the form of load-displacement curves, each containing three rotations and three translations at one intervertebral level. Average +/- SD flexion, extension, axial rotation, and lateral bending ranges of motion to one side were 2.7 +/- 1.3 degrees, 2.4 +/- 1.3 degrees, 1.8 +/- 0.7 degrees, and 3.5 +/- 1.1 degrees, respectively, at level T11-T12. The same ranges of motion at T12-L1 were 2.9 +/- 1.4 degrees, 3.9 +/- 1.4 degrees, 1.2 +/- 0.7 degrees, and 3.7 +/- 1.1 degrees, respectively. The extension and axial rotation ranges of motion at level T11-T12 were found to be significantly different than the same motions at T12-L1. The different geometry in the facet joints explains these observed differences in the mechanical behavior of T11-T12 and T12-L1.

Entities:  

Mesh:

Year:  1992        PMID: 1613631     DOI: 10.1002/jor.1100100412

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  21 in total

1.  Spinal muscle forces, internal loads and stability in standing under various postures and loads--application of kinematics-based algorithm.

Authors:  A Shirazi-Adl; M El-Rich; D G Pop; M Parnianpour
Journal:  Eur Spine J       Date:  2004-09-25       Impact factor: 3.134

2.  Intraoperative determination of the load–displacement behavior of scoliotic spinal motion segments: preliminary clinical results.

Authors:  Christoph Reutlinger; Carol Hasler; Klaus Scheffler; Philippe Büchler
Journal:  Eur Spine J       Date:  2012-08       Impact factor: 3.134

3.  Role of intra-abdominal pressure in the unloading and stabilization of the human spine during static lifting tasks.

Authors:  N Arjmand; A Shirazi-Adl
Journal:  Eur Spine J       Date:  2005-12-07       Impact factor: 3.134

4.  Analysis of squat and stoop dynamic liftings: muscle forces and internal spinal loads.

Authors:  Babak Bazrgari; Aboulfazl Shirazi-Adl; Navid Arjmand
Journal:  Eur Spine J       Date:  2006-11-14       Impact factor: 3.134

5.  Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data.

Authors:  H J Wilke; S T Krischak; K H Wenger; L E Claes
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

6.  Biomechanical in vitro evaluation of the complete porcine spine in comparison with data of the human spine.

Authors:  Hans-Joachim Wilke; Jürgen Geppert; Annette Kienle
Journal:  Eur Spine J       Date:  2011-06-11       Impact factor: 3.134

7.  Junctional susceptibility of the pediatric spine: a case report.

Authors:  Oliver Flouty; Kingsley Abode-Iyamah; Raheel Ahmed; Saul Wilson; Arnold H Menezes
Journal:  Childs Nerv Syst       Date:  2014-09-27       Impact factor: 1.475

8.  A new method to approximate load-displacement relationships of spinal motion segments for patient-specific multi-body models of scoliotic spine.

Authors:  Athena Jalalian; Francis E H Tay; Soheil Arastehfar; Gabriel Liu
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

9.  Is a single anterolateral screw-plate fixation sufficient for the treatment of spinal fractures in the thoracolumbar junction? A biomechanical in vitro investigation.

Authors:  Ulrich Schreiber; Tibor Bence; Thomas Grupp; Erwin Steinhauser; Thomas Mückley; Wolfram Mittelmeier; Rudolf Beisse
Journal:  Eur Spine J       Date:  2004-07-09       Impact factor: 3.134

10.  Patient-specific mechanical properties of a flexible multi-body model of the scoliotic spine.

Authors:  Y Petit; C E Aubin; H Labelle
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.