[Tonometry in change. From indentation and applanation to contour adaptation].

H Kanngiesser1, C Kniestedt.   

Abstract

The dynamic contour tonometer (DCT) is the first and only noninvasive contact tonometer that is capable of measuring intraocular pressure (IOP) directly and continuously. The touch of the pressure-sensitive tonometer tip induces the cornea to gently assume a shape (contour) which it will naturally assume when pressure on both sides is equal. A force field establishes between tonometer tip and cornea, that corresponds exactly to IOP. A piezoresistive pressure sensor, integrated into the surface of the tonometer tip, precisely measures IOP continuously and therefore also records time-dependent modulations of IOP as "ocular pulse amplitude" (OPA). Dependence of the DCT on biomechanical properties of the cornea is substantially smaller than with traditional tonometers that applanate or indent the cornea.

Entities:  

Mesh:

Year:  2005        PMID: 16132995     DOI: 10.1007/s00347-005-1251-1

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  15 in total

1.  [Further contribution to applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1961-06       Impact factor: 3.250

2.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

3.  Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis.

Authors:  Jun Liu; Cynthia J Roberts
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

4.  A new tonometer system.

Authors:  B Grolman
Journal:  Am J Optom Arch Am Acad Optom       Date:  1972-08

5.  Hand-held applanation tonometer.

Authors:  E S Perkins
Journal:  Br J Ophthalmol       Date:  1965-11       Impact factor: 4.638

Review 6.  The non-contact tonometer. Its value and limitations.

Authors:  M B Shields
Journal:  Surv Ophthalmol       Date:  1980 Jan-Feb       Impact factor: 6.048

7.  The ocular pulse.

Authors:  E S Perkins
Journal:  Curr Eye Res       Date:  1981       Impact factor: 2.424

8.  Principle and clinical application of a portable applanation tonometer.

Authors:  J Draeger
Journal:  Invest Ophthalmol       Date:  1967-04

9.  [Studies using applanation tonography].

Authors:  H Goldmann; T Schmidt
Journal:  Doc Ophthalmol       Date:  1966       Impact factor: 2.379

10.  On applanation tonography.

Authors:  H Goldmann; T Schmidt
Journal:  Ophthalmologica       Date:  1965       Impact factor: 3.250

View more
  5 in total

1.  [Evaluation of dynamic contour tonometry in penetrating keratoplasties].

Authors:  An Viestenz; A Langenbucher; B Seitz; Ar Viestenz
Journal:  Ophthalmologe       Date:  2006-09       Impact factor: 1.059

2.  [Ocular pulse amplitude: a new biometrical parameter for the diagnose of glaucoma?].

Authors:  T Romppainen; C Kniestedt; L M Bachmann; J Stürmer
Journal:  Ophthalmologe       Date:  2007-03       Impact factor: 1.059

3.  [Reduction of intraocular pressure and ocular pulse amplitude during general anesthesia].

Authors:  H Zuche; E Morinello; A Viestenz; M Fiorentzis; B Seitz; T Volk; A Viestenz
Journal:  Ophthalmologe       Date:  2015-09       Impact factor: 1.059

4.  [Evaluation of dynamic contour tonometry in keratoconus].

Authors:  N Schädle; J D Unterlauft; T Klink; G Geerling
Journal:  Ophthalmologe       Date:  2009-06       Impact factor: 1.059

5.  Correlation between ocular pulse amplitude measured by dynamic contour tonometer and visual field defects.

Authors:  Chantal Vulsteke; Ingeborg Stalmans; Steffen Fieuws; Thierry Zeyen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-01-12       Impact factor: 3.117

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.