Literature DB >> 17323044

[Ocular pulse amplitude: a new biometrical parameter for the diagnose of glaucoma?].

T Romppainen1, C Kniestedt, L M Bachmann, J Stürmer.   

Abstract

BACKGROUND: Dynamic contour tonometry (DCT) enables accurate transcorneal measurements of the intraocular pressure and ocular pulse amplitude (OPA). In this study, we investigated whether this new biometrical parameter can characterize different glaucoma types and serve as a helpful tool in the diagnosis and therapy of the disease. PATIENTS AND METHODS: A total of 441 eyes of 222 patients were included. Pressure measurements were performed with contour and applanation tonometry.
RESULTS: Mean OPA was 3.1+/-1.4 mmHg. Eyes with ocular hypertension showed significantly higher OPA values (3.6+/-1.3 mmHg) than healthy eyes (3.1+/-1.4 mmHg) and eyes with low-tension glaucoma (2.9+/-1.4 mmHg). After trabeculectomy, the values were significantly lower (2.4+/-1.3 mmHg) than in healthy eyes.
CONCLUSION: The size of the OPA seems to be characteristic for different types of glaucoma and directly dependent on intraocular pressure levels. Further investigation is indicated to clarify its diagnostic usefulness.

Entities:  

Mesh:

Year:  2007        PMID: 17323044     DOI: 10.1007/s00347-006-1467-8

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  27 in total

1.  Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data: prospective analysis of biophysical parameters in tertiary glaucoma practice populations.

Authors:  Christoph Kniestedt; Shan Lin; Joyce Choe; Michelle Nee; Alan Bostrom; Jörg Stürmer; Robert L Stamper
Journal:  J Glaucoma       Date:  2006-04       Impact factor: 2.503

2.  The effect of corneal thickness and corneal curvature on pneumatonometer measurements.

Authors:  Andrew J Morgan; Justine Harper; Sarah L Hosking; Bernard Gilmartin
Journal:  Curr Eye Res       Date:  2002-08       Impact factor: 2.424

3.  [Further contribution to applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1961-06       Impact factor: 3.250

4.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

5.  Ocular pulse amplitude after trabeculectomy.

Authors:  Sandra R von Schulthess; Claude Kaufmann; Lucas M Bachmann; Ahmet Yanar; Michael A Thiel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-07-23       Impact factor: 3.117

6.  Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry.

Authors:  Claude Kaufmann; Lucas M Bachmann; Yves C Robert; Michael A Thiel
Journal:  Arch Ophthalmol       Date:  2006-08

7.  Contact lens tonometry--application in humans.

Authors:  B Entenmann; Y C Robert; P Pirani; H Kanngiesser; P W Dekker
Journal:  Invest Ophthalmol Vis Sci       Date:  1997-11       Impact factor: 4.799

8.  The ocular pulse.

Authors:  E S Perkins
Journal:  Curr Eye Res       Date:  1981       Impact factor: 2.424

9.  Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states.

Authors:  Christoph Kniestedt; Michelle Nee; Robert L Stamper
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-10-13       Impact factor: 3.117

10.  [Ocular blood flow in patients with asymmetric glaucoma].

Authors:  G B Kuba; P Austermann; P Kroll
Journal:  Ophthalmologe       Date:  2002-11       Impact factor: 1.059

View more
  8 in total

1.  [Mobile intraocular pressure measurement. From palpation to initial clinical experience with the handheld dynamic contour tonometer].

Authors:  U Schmid; C Kniestedt
Journal:  Ophthalmologe       Date:  2010-07       Impact factor: 1.059

2.  Ocular pulse amplitude and retrobulbar blood flow change in dipper and non-dipper individuals.

Authors:  R Karadag; U C Keskin; A Koktener; Y Selcoki; I F Hepsen; M Kanbay
Journal:  Eye (Lond)       Date:  2011-03-18       Impact factor: 3.775

3.  Mechanical interferometry of nanoscale motion and local mechanical properties of living zebrafish embryos.

Authors:  Jason Reed; Siddarth Ramakrishnan; Joanna Schmit; James K Gimzewski
Journal:  ACS Nano       Date:  2009-08-25       Impact factor: 15.881

4.  Dynamic contour tonometry in asymmetric glaucoma patients.

Authors:  Emilio Rintaro Suzuki; Cibele Lima Belico Suzuki; Danielle Carlier; Daniele Penha; Marta Dos Anjos Rodrigues Parchen; Wagner Duarte Batista; Joao Agostini Netto
Journal:  Clin Ophthalmol       Date:  2012-04-11

5.  The effect of intravitreal bevacizumab (Avastin) on ocular pulse amplitude in neovascular age-related macular degeneration.

Authors:  Ehud Rechtman; Ingeborg Stalmans; Joseph Glovinsky; Christophe Breusegem; Joseph Moisseiev; Joachim Van Calster; Alon Harris
Journal:  Clin Ophthalmol       Date:  2011-01-06

6.  Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

Authors:  T Bertelmann; S Langanke; M Potstawa; I Strempel
Journal:  Clin Ophthalmol       Date:  2014-07-14

7.  Cyclic RNA hsa‑circ‑000595 regulates apoptosis of aortic smooth muscle cells.

Authors:  Chengfei Zheng; Hui Niu; Ming Li; Hongkun Zhang; Zhenggang Yang; Lu Tian; Ziheng Wu; Donglin Li; Xudong Chen
Journal:  Mol Med Rep       Date:  2015-08-28       Impact factor: 2.952

8.  Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma.

Authors:  Lingyan Cheng; Yuzhi Ding; Xuanchu Duan; Zhifeng Wu
Journal:  Exp Ther Med       Date:  2017-08-30       Impact factor: 2.447

  8 in total